The datalogger can be configured, read out and deleted via
the integrated web interface. The DL2 is additionally equip-
ped with a manual reset button. The following functions can
be carried out by pushing the button:
fill level
•
Deleting the internal memory; the settings will not
data memory
be deleted. For this purpose, press the button for
more than 5 but less than 10 seconds. All LEDs will
be flashing.
•
Resetting the datalogger to the factory settings. For this
purpose, press the button for more than 10 seconds.
reset button
All LEDs will be illuminated. This reset process can take
several minutes.
For data transfer from the internal memory of the DL2,
an SD card can be used:
Insert the SD card into the card slot
«
The status LED flashes green: The card has been
«
re cog nise d a nd d at a are b e ing au t o m at ic a ll y
transferred
After data transfer, the status LED is illuminated
«
(green), the SD card can be removed
For further information about further processing see
ServiceCenter manual
The status LED (integrated into the button) visualises the
operating state of the DL2.
Status LED
off
green flashing
green
Note
The SD card is not used for increasing the
internal memory capacity. It is used for data
transfer only.
no SD card or no mains voltage
SD card has been recognised; DL2
data are being copied to the SD card.
Do not remove the SD card.
SD card can be removed.