Medistrom Pilot-12 Lite Mode D'emploi page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

NOTE: The ResMed AirMini AC adapter can only be used to charge the Pilot-24 Lite
and cannot be used in the Backup Power Supply configuration. To use the ResMed Air
Mini PAP Device in the backup configuration with Pilot-24 Lite please use Medistrom
AC Power Adapter for Pilot-24 Lite (Sold separately, SKU# P24ACCACA) or the original
ResMed AirSense 10 AC power adapter, or the original ResMed S9 power adapter with
the short charging adapter cable.
Using Pilot-24 Lite as a Portable Battery for compatible PAP device
Follow STEP 2 above. Run times will vary based on prescribed pressure, patient
breathing pattern, mask seal, use of any additional features or attachments such as
pressure relief, heated humidifier and heated tubing.
NOTE: For optimal run times while using your Pilot-24 Lite with a compatible PAP
device please disable and/or detach any humidifiers and heated tubing. Mask leaks or
high PAP pressures can greatly decrease run times.
SECTION 2.7 Pilot-24 Lite Specifications
Capacity: 95Wh
Cell Type: LG Industrial grade genuine rechargeable lithium ion cells
Rated Input: 24V, 60W (NORMAL), 90W (MAX)
Rated Output: DC 24V, 3.5A
USB Out: 5V, 2.5A
Life Span: Over 500 full charge/discharge cycles
Case: Aluminum
Dimensions: 9cm x 17cm x 2cm, Weight 1.3lbs
Power Gauge: 4 stage Charge Level Indicator Lights
Recharge time: 2-3 hours (7 to 9 hours via the ResMed AirMini AC Adapter)
SECTION 3 Care Instructions for Pilot Lite
CAUTION! Fully charge your Pilot Lite before storage and at least EVERY 6 MONTHS
thereafter. Failure to do this will be considered negligence and will void the warranty.
CAUTION! Do not expose the battery to liquids of any kind. Keep out of direct sunlight.
If your unit becomes soiled, disconnect it from the power source and the PAP device
and wipe the exterior casing with a clean, dry cloth.
SECTION 4 - Travelling with Pilot-12/24 Lite
The Pilot-12/24 Lite Battery Backup Power Supplies each have a 95Wh capacity. Many
airlines will allow batteries under 100Wh to be taken into the cabin for travel. Please
always consult with your particular airline and flight to confirm that your Pilot-12/24
Lite can be taken with you in your carry-on prior to travelling.
If you plan on charging your Pilot-12/24 Lite with the car charger, please make sure to
test the car charger before travelling.
If you plan on travelling and you have not used your Pilot-12/24 Lite in the battery
configuration, we strongly suggest that you test run the unit in the battery configuration
prior to travelling in order to get an idea of what run-time you could expect. For
optimal run times please disable any additional features such as the heated hose, the
humidifier, EPR as well as properly adjust your mask to minimize air leakage.