4.5 Disposal of filter bags
Dispose of the filter bag in an impervious bag in
compliance with the valid regulations for the disposal
of such wastes.
- Filter bags, filled with normal domestic dirt are
disposed of with the normal domestic waste.
- PE-discharge and disposal bag, filled with
hazardous waste: Enquire at your municipality or
at the responsible authority.
4.6 Inserting the filter bag
4.6.1
Inserting the non-woven filter bag
Pull the flange completely over the intake port.
Operation of the rotary valve
Set the red rotary valve*
inside to CLOSE and turn
until it reaches the stop at the
mark ▲.
Put top part onto container and close lateral
locks.
4.6.2
Inserting the PE-discharge and disposal
bag
Only dust extractors class M and
HEPA with special container and
rotary valve in the intake port of
types S 35 M and S 35 HEPA are
suitable for use with PE-discharge
and disposal bags.
Operation of the rotary valve
Push flange completely over intake port, place
top opening of bag across rim of container.
Put top part onto container and close lateral
locks.
4.7 Emptying the container
Only permissible for dusts with
STELs > 1mg/m3
Switch off suction device, pull power plug.
Open locks.
Remove cover and suction hose from container.
Tip out container.
5
Operation
Danger
The electrical tool must be
switched off when it is connected.
When the power plug is plugged in,
the socket outlet is always live,
irrespective of the switch position.
In switch position "0", the socket
outlet can be used as extension
cord (e.g. for lamp).
Connected load: Dust extractor and
connected device max. 16 A.
-22-
Set the red rotary valve*
inside to OPEN and turn until
it reaches the stop at the
mark ▲.