Instructions To Convert To A Different Type Of Gas; Replacing Injectors - Whirlpool AKR 313 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4. Instructions to convert to a different type of gas

Important:
The replacement of gas injectors shall be
made by a qualified professional or by a
manufacturer's representative.
This cooktop is set for use with liquefied
petroleum gas (LPG), supply pressure of
29 mbar.
Use pressure regulators adequate to the
gas pressures indicated in the installation
instructions.
- If gas conversion injectors are not
included, get in touch with the After-
Sales Service and ask for them.

4.1 Replacing injectors

Important:
This operation shall be made by a
qualified professional, by the gas supplier
or by a manufacturer's representative.
(See injectors table under "Technical
characteristics").
Remove grids (A).
Remove burners (B).
Using a socket spanner of appropriate size
(C), unscrew the injector to be replaced.
Replace it with an injector suitable for the
new type of gas.
Reassemble the injector in (D).
If you have a multiple crown burner, use
side spanner to replace the injector (E).
Manual W10777749.indd 49
Manual W10777749.indd 49
- Adjust minimum supply.
Note:
If liquefied petroleum gas is used (G30/
G31), the minimum gas setting screw must
be tightened as far as it will go.
Important:
Should you experience difficulty in
turning the burner knobs, please get in
touch with the After-Sales Service for
replacement.
Before installing the cooktop, affix the gas
calibration plate supplied with the injectors
so that it covers the existing information
relating to gas calibration.