13 Technical Data
Device information
Compact domestic ventilation unit (exhaust air)
Design
Nominal cylinder volume
Cylinder material
Nominal cylinder pressure
Dimensions W x H x D (overall)
Weight (empty)
Electrical connection
Fuse
Refrigerant R134a, total filling weight
Performance data
Air temperature operating range of heat pumps
Selectable water temperature (heat pump operation
Heating-up period from 15 °C to 60 °C
Power consumption supplementary electric heating
1
Mean power consumption
1
Mean heat output
COP (t) according to EN 255
Stand-by energy consumption
2
Sound pressure level
Air flow: level I / II / III
Mean power consumption - fan level I / II / III
External compression
Air duct connection cross-section
Transfer area of the internal heat exchanger
Sensor pipe ∅
(for heat exchanger operation)
internal
Circulation pipe connection
Hot water outlet connection
Cold water inlet connection
Internal heat exchanger connection
1. Heating up of the nominal volume from 15 °C to 45 °C with L20 / F50 = exhaust air temperature 20 °C and exhaust air humidity 50% and fan level III
2. At a distance of 1 m (free-standing installation or installation without exhaust air duct or 90° pipe bends on the exhaust air side)
www.dimplex.de
(litre)
(bar)
(cm)
(kg)
(A)
(kg)
(°C)
±1.5K
)
(°C)
at (L20 / F50)
(h)
(Watt)
at 45 °C
(Watt)
at 45 °C
(Watt)
at 45 °C
at 45°C / 24h
(Watt)
(dB(A))
3
(m
/h)
(W)
(Pa)
(mm)
(m²)
(mm)
external thread
external thread
external thread
external thread
LWP 300W
With additional internal heat exchanger
290
Enamelled steel according to DIN 4753
10
66 x 65 x 170
Approx. 175
230V ~ 50Hz
16
0.8
15 to 30
23 to 60
10.3
1500
470
1590
3,4
47
53
120 / 185 / 230
15 / 28 / 45
200
160
1.45
12
R 3/4"
R 1"
R 1"
R 1"
13
E-11