English
! The appliance must be installed by a qualified person
EN
in compliance with the instructions provided.
!
Wear gloves and goggles when carrying out
installation and maintenance operations.

AIR VENT

(for ducting versions)
! Prepare the hole and the air vent duct (150 mm
diameter).
! Use a duct of the minimum indispensible length.
! Use a duct with as few elbows as possible (maximum
elbow angle: 90°).
! Avoid drastic changes in the duct cross-section.
! Use a duct with an as smooth as possible inside.
! The duct must be made of certified material.
! Do not connect the hood to smoke exhaust ducts for
the products of combustion (boilers, fireplaces,
stoves, etc).
! For the air vents comply with the provisions laid down
by the competent authorities.
In addition, the air must not be evacuated through a
hole in the wall unless specifically intended for this
purpose.
! Fit air intakes in the room to prevent the hood from
creating a negative pressure in the room (which must
not exceed 0.04 mbar); if the hood is used at the
same time as non-electrical equipment (gas-, oil- and
charcoal-fired stoves, etc.) the exhaust gas may be
sucked in by the heat source.
! For installation with a wall vent hole, power should be
provided in the area indicated by
template
FILTERING OR DUCTING VERSION ?
The hood may be in filtering or in ducting version.
Decide from the outset which type is to be installed.
For better efficiency, we recommend installing the hood
in the ducting version (if possible).
Ducting version
The hood purifies the air and evacuates it to the outside
through an exhaust duct or hole (diameter 150 mm).
Filtering version
The hood purifies the air and recycles the clean air
back into the room. For this version, the following is
required: a theft-proof cover, a reducer and charcoal
filter. In the version with flue, the upper flue must have
the air evacuation slots positioned in the upper part and
the deflector must be used in place of the anti-theft
cover.
CONTROLS
Speed display
PU5: ON/OFF SENSOR
PU4: ON/OFF Motor 3
PU3: ON/OFF Motor 2
PU2: ON/OFF Motor 1
*PU1: ON/OFF Lights
Buzzer:
Each time the key is pressed, a beep is sounded.
- AUTOMATIC function (Sensor)
Once the PU5 key is pressed, the speed of the motor
is automatically set by the sensor and is displayed by
the corresponding LED (fixed light). For each automatic
change of speed, the LED of PU5 blinks for 5 seconds.
During automatic operation it is in any case possible to
on the drilling
vary the speed of the motor by using the corresponding
buttons. When the function is active, pressing the PU5
key turns the motor on/off.
Setting of the sensor sensitivity
With the motor stopped, and the automatic function
deactivated, press both the PU1 and PU5 keys
simultaneously for 3 seconds.
The LED of PU2 (minimum sensitivity) or of PU3
(medium sensitivity) or of PU4 (maximum sensitivity)
indicate by blinking the current level of sensitivity.
Select the desired level of sensitivity:
PU2: minimum sensitivity
PU3: medium sensitivity
PU4: maximum sensitivity
Press the PU5 key to save the choice.
- Filter alarm:
After 30 hours of motor operation, the grease filter alarm is
activated (all the LEDs come on). The alarm is activated
when the motor is off and remains displayed for 30". To
deactivate the alarm, press one of the keys for 2" during
alarm display. After 120 hours of motor operation, the
charcoal filter alarm is activated (all the LEDs blink). The
alarm is activated when the motor is off and remains
displayed for 30". To deactivate the alarm, press one of the
keys for 2" during alarm display.
14
KEY
LED
speed
rd
speed
nd
st
speed
*Only for the SMOOTH model
With pressing held, the PU1 key also
turns the upper LED of the hood on/off.