Log Grate Installation
Only use filtered tap water in this appliance.
Once installed, never move this appliance or lay it on its back, without draining the water from the
sump and water tank.
If you intend not using the appliance for longer that 2 weeks, drain the water from the reservoir
and refill container.
The refill container, reservoir, cover and container cap must be cleaned once every two weeks,
particularly in hard water areas.
1) Fill and install the Refill Container.
Note: During initial installation, the Refill Container shouldd be refilled after the Reservoir has filled
to ensure maximum operation time.
2) Make sure sure the On/Off switch is switched to Off (refer to Operating Instruction section)
3) Assemble power adapter (Fig. 2). Plug the power adaptor into the front of the unit, then plug the
unit into a power socket
Operation
The manual controls for the Log Grate are located on the right side (Fig. 3).
A. On/Standby Switch.
Supplies power to the Log Grate
B. Momentary Button
Pressing this button toggles between Logs, Logs and flame effect, and Standby.
Remote Control
The unit is supplied with a radio frequency remote control. This remote control has a range of
approximatly 15m. It does not have to be pointed at the fireplace and can pass through most
obstacles (including walls). It is supplied with one of 243 independent frequencies to prevent
interference with other units. The frequency designation is indicated on the back of the remote
control.
Note: Before attempting any operation with the remote control, pull the plastic insulator strip out
from between the remote casing and the battery cover (Fig. 4).
Remote Control Initialisation/Reprogramming
Follow these steps for remote control initialisation and if required, re-initialisation;
1.
Unplug the power adaptor from the unit.
2.
Wait a minimum of five seconds and then plug the power adapter back into the unit
3.
Within ten seconds of re-acquiring power, press the ON button located on the remote
control (Fig. 4)
This will synchronize the remote control and the receiver
Remote Control Usage
Pressing the On button, on the remote control, switches between the two levels:
Level 1: The Logs and lights are turned on.
Level 2: The logs and lights remain on and the flame effect is activated.
The fireplace can be turned off at any point by pressing the OFF button on the remote control.
Note: Once the mist has been activated, the unit will have to be turned Off, using either the
momentary button, on the unit, on the Off button or the remote control, then back on to return to
Level 1 - Logs and Lights only in operation.
4