Maytag MEDB850WR Guide D'utilisation Et D'entretien page 13

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3. Connect ground wire (green or bare) of direct wire cable to external ground conductor
screw. Tighten screw.
A
B
C
D
A. External ground conductor screw
B. Neutral ground wire
C. Ground wire (green or bare) of power supply cord
D. ¾" (19 mm) UL listed strain relief
E. Center, silver-colored terminal block screw
F. Neutral wire (white or center wire)
4. Place the hooked ends of the other direct wire cable wires under the outer terminal block
screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
5. Tighten strain relief screw.
6. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-
down screw.
7. You have completed your electrical connection. Now go to "Venting Requirements."
3-wire connection: Power supply cord
Use where local codes permit connecting cabinet-ground conductor to neutral wire.
E
A
F
1. Loosen or remove center, silver-colored terminal block screw.
2. Connect neutral wire (white or center wire) of power supply cord to the center, silver-
colored terminal screw of the terminal block. Tighten screw.
B
D
C
A. 3-wire receptacle (NEMA type 10-30R)
B. 3-wire plug
C. Neutral prong
D. Spade terminals with upturned ends
/
E.
3
" (19 mm) UL listed strain relief
4
F. Ring terminals
G. Neutral wire (white or center wire)
A
B
A. External ground conductor screw
B. Neutral ground wire
C. Center, silver-colored terminal block screw
D. Neutral wire (white or center wire)
/
E.
3
" (19 mm) UL listed strain relief
4
E
F
G
C
D
E
13

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bravos

Table des Matières