FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050
IMPROPER INSTALLATION
The use of other components other than stated
herein could cause bodily harm, heater damage, and
void your warranty. The manufacturer will not be held
responsible for damage caused by the malfunction
of a stove due to improper venting or installation.
FLOOR PROTECTION
This heater must have a non-combustible floor
protector
(UL1618
ember
beneath it if the floor is of combustible material.
US - Floor protector should be UL listed or equal too,
needs to extend 6" to the front, 6" to each side, 1" to
the rear of the unit. Under and 2" beyond each side
of the cleanout tee if an interior vertical installation.
Canada - Floor protector should comply with CAN/
ULC standards. Needs to extend 18" to the front, 8"
beyond each side of the unit.
A
Back to Stove
B
Side to Stove
C
Front to Stove
D
Back to Flue
© 2021 United States Stove Company
protection)
installed
U.S.A
1"
26 mm
CAN
8" 204 mm
U.S.A
6"
153 mm
CAN
8" 204 mm
U.S.A
6"
153 mm
CAN
8" 204 mm
2"
51 mm
CLEARANCES
Your pellet stove has been tested and listed for
installation in residential, mobile home in accordance
with the clearances given below. For safety reasons,
please
adhere
to
and restrictions. Any reduction in clearance to
combustibles may only be done by means approved
by a regulatory authority.
E
Side Wall to Stove
F
Side Wall to Vent Pipe
G
Back Wall to Stove
H
Back Wall to Vent Pipe
J
Ceiling to Floor
K
Ceiling to Stove
L
Side Wall to Stove
M
Side Wall to Vent Pipe
N
Back Wall to Vent Pipe
-6-
INSTALLATION
the
installation
clearances
10"
245 mm
11-1/2"
292 mm
11-7/8"
302 mm
3"
76 mm
84"
2134 mm
53-7/8'
1434 mm
7-1/2"
191 mm
11-1/4"
286 mm
7-1/2"
191 mm