• Binders – Some pellets are produced with materials
to hold the together, or "bind" them.
• High ash content – Poor quality pellets will often
create smoke and dirty glass. They will create a need
for more frequent maintenance. You will have to
empty the burn pot plus vacuum the entire system
more often. Poor quality pellets could damage the
auger. We cannot accept responsibility for damage
due to poor quality pellet.
CAUTION:
• KEEP FOREIGN OBJECTS OUT OF THE HOPPER.
• THE MOVING PARTS OF THIS STOVE ARE
PROPELLED BY HIGH TORQUE ELECTRIC
MOTORS. KEEP ALL BODY PARTS AWAY FROM
THE AUGER WHILE THE STOVE IS PLUGGED
INTO AN ELECTRICAL OUTLET. THESE MOVING
PARTS MAY BEGIN TO MOVE AT ANY TIME
WHILE THE STOVE IS PLUGGED IN.
PRE-START-UP CHECK
Remove burn pot, making sure it is clean and none
of the air holes are plugged. Clean the firebox, and
then reinstall burn pot. Clean door glass if necessary
(a dry cloth or paper towel is usually sufficient). Never
use abrasive cleaners on the glass or door. Check fuel
in the hopper, and refill if necessary.
BUILDING A FIRE
Never use a grate or other means of supporting the
fuel. Use only the burn pot supplied with this heater.
Hopper lid must be closed in order for the unit to
feed pellets. During the start-up period:
1.
Make sure the burn pot is free of pellets.
2. DO NOT open the viewing door.
3. DO NOT add pellets to the burn pot by hand.
NOTE: During the first few fires, your stove will emit
an odor as the high-temperature paint cures or
becomes seasoned to the metal. Maintaining smaller
fires will minimize this. Avoid placing items on the
stovetop during this period because the paint could
be affected. Attempts to achieve heat output rates
that exceed heater design specifications can result
in permanent damage to the heater.
AUTOMATIC IGNITOR
Fill hopper and clean burn pot.
1.
Press "On/Off" button. Make sure green light
comes on.
© 2021 United States Stove Company
OPERATION INSTRUCTIONS
2. Adjust feed rate to desired setting by pressing
"Heat Level Advance" button.
If fire doesn't start in 12 minutes, press "On/Off",
wait a few minutes, clear the burn pot, and start
procedure again.
DAMPER CONTROL
The damper control lever is located on the back of
the stove on the lower left side. The default setting for
the damper control should be full open. The damper
adjusts the combustion air. This control is necessary
due to the varied burn characteristics of individual
installations, different pellet brands and pellet feed
rates. It allows you to improve the efficiency of your
stove. Providing correct combustion air will reduce
the frequency of cleaning your glass door and
prevent the rapid buildup of creosote inside your
stove and chimney. You should adjust the damper
based on the fire's appearance. A low, reddish, dirty
fire can be improved by turning the damper slightly
to the right. A "blow torch" fire can be improved by
turning the dampener to the left a little bit.
OPENING DOOR
• DO NOT OPERATE YOUR STOVE WITH THE
VIEWING DOOR OPEN. THE AUGER WILL NOT
FEED PELLETS UNDER THESE CIRCUMSTANCES
AND A SAFETY CONCERN MAY ARISE FROM
SPARKS OR FUMES ENTERING THE ROOM.
• THE FEED DOOR MUST BE CLOSED AND SEALED
DURING OPERATION.
If the door is opened while the stove is in operation
it must be closed within 30 seconds or the stove will
shut down. If the stove shuts down push the "On/
Off" button to re-start your stove. The stove will have
to fully shut down and turn off before you will be able
to restart the stove.
-12-
CAUTION:

Publicité

Table des Matières
loading