FLEXIBLE DUCT ASSEMBLY
Ductwork outside of the heated spaces:
Use of flexible ducts or insulated circular
ducts
Outside of the heated spaces it is imperative that
50 mm insulated ducts are used.
• Ensure the ductwork is sealed around the sleeves
and connectors by adding a fixing collar or
specially-designed CMEV glue.
• Avoid unnecessary bends.
• Stretch the duct out into straight lines.
1
1
Distribution casing
Use of the insulating PPE distribution casing
• Facilitates connections
• Mounting in the ceiling, or suspended using threaded studs
• Configurable depending on the type of connection (Ø 125 or Ø 80),
and their number (caps)
2
2
32
• Do not crush ducts and leave them visible so that
another person will not crush them.
• The discharge must be connected to the outside using
a special CMEV roof exhaust.
1 - Connect the inner duct to the
2 - Bring the insulating cover over
Grille connections
1 - Fix the duct to the sleeve.
Turn and push the sleeve
2 - Insert the grille into the sleeve and connect it electri-
cally (see electric connections)
Warning. Do not forget to connect the kitchen grille
electrically. On first use it is necessary to wait
15 mins after powering on before being able
to use the kitchen electric grille.
connector
the duct and hold it in place
using the easyclip collar.