Defi Nitions; Elbow Vent Length Values - Napoleon Ascent X 36 Série Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

venting requirements
EN
2.5
defi nitions
For the following symbols used in the venting calculations and examples are:
> - greater than
> - equal to or greater than
< - less than
< - equal to or less than
H
- total of both horizontal vent lengths (Hr) and offsets (Ho) in feet
T
H
- combined horizontal vent lengths in feet
R
H
- offset factor: .03 (total degrees of offset - 90°*) in feet
O
V
- combined vertical vent lengths in feet
T
2.6

elbow vent length values

FEET
INCHES
0.03
15°
0.45
30°
0.9
11.0
45°
1.35
16.0
90°*
2.7
32.0
* The fi rst 90° offset has a zero value and is shown in the formula as - 90°
16
W415-1849 / A / 03.06.19
MILLIMETERS
0.5
12.7
6.0
152.4
279.4
406.4
812.8

Publicité