Safety Considerations; Safe Installation Requirements; Danger, Warning And Caution - ICP ODH53F100LB-3MC Guide D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SAFETY CONSIDERATIONS

INSTALLATION OF OIL FIRED HEATING UNITS
SHALL BE IN STRICT ACCORDANCE WITH THE
REGULATIONS OF THE AUTHORITIES HAVING
JURISDICTION. IN CANADA, CSA B139 AND IN THE
UNITED STATES, NFPA NO.31-1992 INSTALLATION
CODES FOR OIL BURNING EQUIPMENT APPLY.
DO NOT OPERATE FURNACE IN A CORROSIVE
ATMOSPHERE CONTAINING CHLORINE, FLUORINE
OR ANY OTHER DAMAGING CHEMICALS.
DO NOT STORE OR USE GASOLINE, OR OTHER
FLAMMABLE VAPOURS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE.
1.1)
SAFETY LABELLING AND WARNING SIGNS

DANGER, WARNING AND CAUTION

The words DANGER, WARNING and CAUTION are used to identify
the levels of seriousness of certain hazards. It is important that you
understand their meaning. You will notice these words in the manual
as follows:
DANGER
Immediate hazards which WILL result in death or
serious injury.
WARNING
Hazards or unsafe practices which CAN result
in death or injury.
CAUTION
Hazards or unsafe practices which CAN result in
personal injury or product or property damage.
PART 1
INSTALLATION
1.2)

SAFE INSTALLATION REQUIREMENTS

Installation or repairs performed by unqualified
persons can result in hazards to them and others.
Installation MUST conform to local codes or, in the
absence of same, to codes of the country having
jurisdiction.
The information contained in this manual is
intended for use by a qualified service technician
familiar with safety procedures and equipped with
the proper tools and test instruments.
Failure to carefully read and follow all instructions
in this manual can result in personal injury and/or
death, property damage, furnace malfunction.
Fire hazard.
The furnace must be installed in a level position;
never where it will slope toward the front.
If the furnace is installed in that position, oil will
drain into the furnace vestibule and create a fire
hazard,
combustion chamber.
NOTE: It is the personal responsibility and obligation of the customer
to contact a qualified installer to ensure that the installation conforms
to governing local and/or national codes and ordinances.
a.
This furnace is NOT approved for installation in mobile homes,
trailers or recreational vehicles;
b.
Do NOT use this furnace as a construction heater or to heat a
building under construction;
c.
There must be a sufficient supply of fresh air for combustion as
well as ventilation in the area where the furnace is located;
d.
Use only the type of fuel oil approved for this furnace (see Rating
Plate on unit). Overfiring will result in heat exchanger failure and
cause dangerous operating conditions;
e.
Visually check all oil line joints for signs of leakage;
f.
Connect furnace to a side-wall terminal or chimney;
g.
The points in Part 2 "Operation" are vital to the proper and safe
operation of the heating system. Take the time to ensure that all
steps were followed;
h.
Follow the regulations of the ANSI / NFPA No.31 (USA) and
B-139 (Canada) or local codes for placing and installing the oil
storage tank;
i.
Follow a regular service and maintenance schedule for efficient
and safe operation;
445 01 4024 03
WARNING
WARNING
instead
of
being
directed
into
the
3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ocf105a12c

Table des Matières