EXTERIOR BLOWER SELECTION
CAUTION: To reduce the risk of fire and electric shock, install this rangehood only
with EB6, EB9, EB12 or EB15 Exterior Blowers.
The exterior ventilator must be UL listed for Canadian and U.S. use, and evaluated
for use with solid state speed control, rated 120V, 60 Hz, 6.0 A max.
INSTALL THE DUCTWORK
NOTE: To reduce the risk of fire, use only metal ductwork.
1. Choose the location where the exterior blower will be mounted. See illustra-
tions below for mounting location suggestions and restrictions.
2. A straight, short duct run will allow the hood to perform most efficiently.
3. Long duct runs, elbows and transitions will reduce the performance of the
hood. Use as few of them as possible. Larger ducting may be required for best
performance with long duct runs.
4. After the exterior blower has been installed, connect round metal ductwork and
work back towards the hood location. Use duct tape to seal joints between
ductwork sections.
5. An 8" round to 10" round transition (Model 414) is required. For best air
performance, install the adapter as close to the range hood as possible.
SUGGESTED MOUNTING LOCATIONS
OK
OK
CAUTION: MAY NOT
FIT UNDER EAVES
OF SINGLE STORY
HOMES
- 8 -
10" ROUND
DUCT
8" ROUND
DUCT
DECORATIVE
FLUE
HOOD
24" TO 30" ABOVE
COOKING SURFACE
(See "INSTALL
MOUNTING BRACKET"
SECTION, page 9, for
mounting restrictions)
EXTERIOR
BLOWER
8" TO 10"
ROUND
ADAPTER
EXTERIOR
BLOWER
10"
ROUND
DUCT
8" ROUND
ELBOW