Installation Instructions; Technical Data; Packing Unit; For The Fitter - AEG RTi 100 M Notice D'utilisation Et De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2. Installation Instructions

The room temperature regulator must be fitted by an authorised specialist under consideration
of the these operation and installation instructions and the operating and installation instruc-
tions of the storage heater.
All electrical connection and installation work must be performed in accordance with the VDE
regulations 0100, the regulations of the electricity supply company responsible and the pertinent
national and regional regulations.

2.1 Technical Data

Model
Rated voltage
Connection rating

2.2 Packing Unit

1 room temperature regulator with outside sensor, heating band 2-3 W as thermal
feedback (already pre-installed on the mounting plate)
1 temperature selector knob
1 ON/OFF switch with 2 wires
1 radio interference suppressor 0.2 µF, 47 ohms
3 screws
1 operating and installation instructions
1 circuit diagram label
1 control panel label
2.3 Installation
Disconnect the storage heater from the power supply before starting installation work.
When connecting the storage heater to an automatic charging control unit, there may be
voltage at the terminals A1/Z1 and A2/Z2 even when the fuses are removed.
When installing several storage heaters in a row make sure that the room temperature regulator is
installed in the outside right unit. This guarantees that the room temperature can be measured
properly.
2.3.1 Order of Installation
• Remove air outlet and inlet grille, front wall and right side wall as described in the storage
heater operation and installation instructions.
• Press the dummy caps (1) for switch and temperature selector knob out of the control panel at
the top and bottom left from the switching area side using a suitable tool.
• Installation of the ON/OFF switch:
Push the enclosed black wires (short and long) with the flat connectors onto the switch (2)
through the holder (3) and snap the holder onto the metal bracket (4).
• Press the On/Off switch (2) with the symbol „I" into the right of the holder.
• Mount the temperature regulator (5) with the 2 screws and toothed washers on the bracket (4).
• Attach the preassembled unit consisting of sensor bulb, heating strip, spacer frame and support
plate (6) to the upper sheet-metal bracket of the control panel (support plate of terminal strips
X1 and X2). To do so, engage the lower sheet-metal bracket behind the locking tab of the upper
sheet-metal bracket (8). The two brackets are joined together by means of a screw (M4x8).
RTi 100 M
1/N/PE ~ 50 Hz 230 V
16 A

For the Fitter

11

Publicité

Table des Matières
loading

Table des Matières