Freely Configured Sensor With 2 Switching Outputs - IFM efector500 PP70 Série Notice Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Freely configured sensor with 2 switching outputs

Set the following parameters:
• Switch-on points and switch-off points (SP1, rP1, SP2, rP2)
• Switching function of the outputs (OU1, OU2)
Switching function
(can be selected for
each output separately)
Additionally you can set:
• Delay time and damping for the switching outputs (dS1, dr1, dS2,
dr2, dAP)
p-switching or n-switching
Observe the instructions for installation and electrical connec-
tion (page 21).
Connect the unit according to the configuration:
2 x p-switching
BN
1
WH
2
4
BK
BU
3
Core colours of ifm sockets:
1 = BN (brown), 2 = WH (white), 3 = BU (blue), 4 = BK (black)
After mounting, wiring and setting check whether the unit
operates correctly.
output 1
hysteresis function / N.O. (Hno)
hysteresis function / N.C. (Hnc)
window function / N.O. (Fno)
window function / N.C. (Fnc)
(P-n)
L +
OU2
OU1
L-
output 2
2 x n-switching
BN
1
WH
2
4
BK
BU
3
4
L +
OU2
OU1
L-
25

Publicité

Table des Matières
loading

Table des Matières