Fitting procedure
3. Installing the wall-hanging bracket on the wall
Note
• This wall-hanging bracket can also be installed vertically. (However, the bracket can only be used in the "Zero tilting"
position when installed vertically.)
Determine the positions of the wall mounting holes based on the external dimensions drawings (see pages 83
and 84), and attach the bracket to the wall.
Horizontal installation Attach the wall-hanging bracket with the arrows facing up.
Adjusting the angle
The angle of this wall-hanging bracket can be adjusted in 5-degree increments to one of five positions ranging
from "Zero tilting" to "20-degree tilting".
The wall-hanging bracket is shipped from the manufacturing plant in the "Zero tilting" angle position. To change
the angle, use the angle adjustment screws to change the position of the stay.
(Tightening torque: 1.2 to 1.5 N•m)
"20-degree tilting"
"Zero tilting"
"15-degree tilting"
"10-degree tilting"
"5-degree tilting"
Vertical installation Attach the wall-hanging bracket with the direction indicated by "L" at the top.
• When the plasma display is installed vertically, be careful because the center position of the plasma display
will differ from the center position of the bracket due to the structure of the wall-hanging bracket.
Use screws or nuts with a nominal diameter of 6 mm (0.2 inches) to firmly secure the bracket at all of the six
mounting hole positions.
Notes
• For the wall mounting screws, use commercially available screws with a nominal diameter of 6 mm (0.2 inches) that are
suited to the material/structure to which you are fitting the bracket.
• Check the strength of the mounting screws. Use screws that are sufficiently strong.
• If you are embedding the screws, make sure they protrude from the wall surface by 10 to 15 mm (0.4 to 0.6 inches).
• Anchor the screws in at least six locations.
Horizontal installation
Screw for
securing unit
14
Stay
"Zero tilting"
"Tilting from 5 to 20
degrees"
Unit: mm (inches)
58 (2.3)
58 (2.3)
684 (27.0)
Arrows
Push the screw through
to this position.
When the angle is set to
"Zero tilting"
Angle
adjustment
screws
Vertical installation
Screw for securing unit
Screw for securing unit
When the angle is set to
"15-degree tilting"
Unit: mm (inches)
300 (11.9)
(Bracket base
left fitting)
L
*Use in the "Zero Tilting" position.