Fitting procedure

1. Assembling the wall-hanging
bracket
Place the base upper and lower fittings
① and base left ② and right ③ fittings as
shown in the diagram.
Insert the projecting parts (tabs) of the
base left and right fittings into the cutouts
of the base upper and lower fittings (two
positions on right, and two on left), and
secure the fittings with the screws for
assembling the fixtures ④ (two for each).
(Tightening torque: 1.2 to 1.5 N•m)
Note
• Please hold the bracket base left and right
fittings as you work with the assembled wall
hanging bracket. Holding the base upper and
lower fittings might deform this unit.
2. Checking the strength of the
installation location
The wall-hanging bracket weighs
approximately 6.0 kg (13.3 lbs).
Refer to the instruction manual of the
plasma display, and check the weight of the
plasma display unit which will be fitted into
the wall-hanging bracket.
Refer to the outline drawing of the wall-
hanging bracket shown on the right,
and check the wall strength at the six
installation positions shown. If the strength
at any of these positions is lacking, provide
sufficient reinforcement.
Notes
• There are nine pre-drilled mounting holes at the
top and bottom of the wall-hanging bracket. Use
the spare holes provided if wood or some other
material is used for the wall and a sufficient
level of mounting strength cannot be ensured
by anchoring the fixture at the six positions
shown on the right. However, bear in mind that,
depending on which materials the mounting
surface is made of, cracks may form on the
surface if the screws are used at positions which
are too close together.
• Do not mount or place any other product other
than the plasma display on the fixture.
• For details on the dimensions applying when the
plasma display is mounted, refer to the outline
drawing (See page 83-84).
Base upper and lower fitting
Bracket base
left fitting
Bracket base
right fitting
L
Base upper and lower fitting
58 (2.3)
mark : Wall mounting holes (at 6 points)
The bracket must be fixed by screws.
Outside (A): 65V model
Inside (B): 58V model
Tab
R
Cutout
Screw for assembling the fixture
Unit: mm (inches)
800 (31.5)
58 (2.3)
684 (27.0)
440 (17.4)
520 (20.5)
600 (23.7)
630 (24.9)
730 (28.8)
760 (30.0)
Tab