CLEANING AND MAINTENANCE
1. Cleaning of the circulating system and the filtration system is recommended
once a month or once two months for optimum refrigeration operation and
efficiency, unplug the cord from the outlet before cleaning. Rinse collected
debris from the filter media, inlet & outlet pipe, flow diverter, impeller and
chamber cover with clear lukewarm tap water. Soap or detergents are not
recommended for filter maintenance because they are bad for the fish's health.
( Fig.1)
2. Remove the dust at the filter (Front draft hood), air inlet and outlet with a
brush or vacuum cleaner. To avoid electric shock, during operation, do not
insert wire into the exhaust outlet or the air inlet. ( Fig.2 )
3. The electric supply switch and temperature adjuster must be cleaned with
dry soft cloth. ( Fig.3 )
4. Neither immerse the unit into water nor flush it with water directly to avoid to
damage the electric insulation of the chiller. ( Fig.4 )
5. Disconnect the power supply plug if the unit will not be used for a long time,
remove the inlet & outlet pipes, then lift the back of the chiller a bit to remove
water in the chiller, clean all the parts with a piece of soft cloth and cover it with
a vinyl bag, put it into the color box, then store it in a safe and dry place.
( Fig.5 )
6. If the supply cord is damaged, it must be replaced by the manufacturer or its
service agent or a similarly qualified person in order to avoid a hazard.
7. If you still have any other questions, please contact with our dealer or an
Authorized Service Center near your home. ( Fig.6 )