Note on the duplex house version: one 4-pole connection
terminal is provided per residential unit; the connector terminals are
numbered. Terminal 1 is for the lowest bell button, terminal 2 for the
bell button above it.
Connecting a door opener
The door opener is connected directly to the outdoor station by two
lines (figure 2.2, no. 12). No additional power supply is necessary
to control the door opener. The door opener must be designed for 12
V direct current and may not require more than 1 A current. The two
connector terminals are marked 'Doorlock' and 'GND' if the door opener
needs to be poled. 'GND' is negative.
Connecting the power supply
The power supply can either be connected to the indoor or to the out-
door station. Separate screw terminals exist for this purpose (figure 2).
It is also possible to connect the power supply directly to the signal line,
e.g. if all signal lines have been laid from the fuse box to the outdoor
and indoor units. The power supply unit then needs to be connected
with earth (GND) and +15V.
Up to 8 units can be supplied with power from one power supply unit. A
second power supply unit is required if there are more than eight units,
e.g. if 2 outdoor and 7 indoor stations need to be used.
The second power supply unit can simply be switched parallel to the
first power supply unit.
The second power supply unit should be connected with a short line to
the indoor or outdoor station that is farthest away so that any drop in
current in the connection line can be compensated.
Connecting an external camera
An external camera can be connected to this screw terminal (figure 2)
in order, for example, to provide additional monitoring of areas that
cannot be seen by the main camera. All cameras can be connected that
require operating voltage of 12 V DC and supply an FBAS video signal.
The video line is connected to the terminal (VIDEO IN) and the earth
line to the terminal (GND), operating voltage for the camera is taken
from the terminals '+12V DC OUT' (positive pole) and 'GND' (negative
pole).
The external camera automatically has the ID 4 (see chapter on ID
code).
No sound transmission is possible when the external camera is active.
When using the VDV 500 XCam, the X-module is not needed.
POSSIBLE SETTINGS
The outdoor station offers the following possibilities to set the system
to your personal circumstances:
Volume of the outdoor station
The potentiometer (7) is used to set the volume on the outdoor station.
To set the highest volume, turn the potentiometer carefully clockwise
as far as possible. Reduce the volume by turning in an anti-clockwise
direction.
ID code
If several outdoor stations are switched in parallel (e.g. at the gate ent-
rance and the house) then the ID code is set via the dip switch (9). This
makes it possible to activate the individual outdoor units in sequence,
e.g. in order to monitor the coverage of the relevant outdoor unit. The
switch is carried out on the indoor station with the 'monitor' switch.
ID1 = Switch 1 'on' Switch 2 'on'
ID2 = Switch 1 'off' Switch 2 'on'
ID3 = Switch 1 'off' Switch 2 'off'
Opening time of the door opener
The DIP switch (8) is used to set the time the door opener remains
activated. The options are either 1 second or 5. The factory setting is 5
seconds, which works for most conventional door openers.
Switch to the left to "5S" for 5 seconds open time.
Switch to the right to "1S" for 1 second open time.
OPERATION
1. Press the bell push-button.
2. The preset ring tone sounds on its inside station/s and the screen
displays the outside station view.
3. Accept the dialogue on the inside unit by briefly pressing the press-
to-talk button (MOUTH).
4. If an additional camera is present at the outside station, you may
switch over to this camera by pressing the "MONITOR" button.
Pressing the „Monitor" button again switches you back to the
internal camera.
5. If a door opener is connected then you can activate the door
opener by pressing briefly on the door opener button (KEY).
6. Switch the system back to standby operation by briefly pressing the
speak button (MOUTH).
TECHNICAL DATA
Operating voltage:
15 V DC
Current consumption:
130 ± 50 mA
Camera detection angle:
135° horizontal / 100° vertical
Temperature range:
-10°C to +50°C
Dimensions (w x h x d):
114 x 195 x 24 mm (without lens)
Door opener connection:
DC 12V, max. 1A
INFORMATION
Information regarding CE - Conformity
The functionality of the unit can be affected by the influence of strong
static, electrical or high frequency fields (discharging, mobile phones,
radios, microwaves).

Cleaning and maintenance

Always disconnect mains powered units from the mains supply before
cleaning (disconnect the plug). The unit housing can be cleaned using
a soapy soft cloth. Do not use any abrasive materials or chemicals.
Remove dust build-up from ventilation slits using a brush and clean up
using a vacuum cleaner. Do not hold the vacuum cleaner nozzle directly
against the unit.
Safety instruction
In the event of damage to the housing, connectors, power cables or
isolation shielding, switch off the device immediately and disconnect
from the mains power. ELECTRIC SHOCK – DANGER OF
LOSS OF LIFE. (Unplug the mains connector from the socket!).
7