EN
TROUBLESHOOTING.
Point
Description
1
The thermal protection warning
light (3) lights up.
2
The welding current selector does
not work.
3
The engine fan does not work, or
the rotation speed is low.
4
No open circuit voltage in the
welding terminals.
5
The cable of the electrode holder,
the
output
terminal
equipment or the plug are too hot.
6
The device does not start or shuts
down immediately after starting.
7
Warning!
The equipment has a built-in function that prevents switching the on/off
switch (9) successively and quickly within a short period of time, so that, shall this occur, the
equipment will stop working even if connected with the switch in the ON position. Turn the
switch to the OFF position and restart the device normally after a few minutes.
WARRANTY.
Duration: The guarantee period is 24 months for users who do not carry out a professional
activity with the equipment. The warranty period is 12 months in all other cases.
Coverage: The guarantee requires the manufacturer CEVIK S.A. to repair or replace for free all
components subject to verified manufacturing flaws. The CEVIK Assistance Service will be
responsible for the repair or replacement in the shortest possible time, compatibly with the
internal commitments of the service, without any obligation of compensation or reparation for
direct or indirect damages.
Possible cause
Poor ventilation in the work area that
activates
the
overheating
Working cycle range (operating factor)
exceeded.
Damaged potentiometer.
The power switch (9) is in the OFF
mode.
The power switch (9) does not work.
Damaged fan.
Excessive heating
The power switch (9) does not work.
The electrode holder or cable have
of
the
exceeded their capacity; an electrode
with a diameter greater than that
recommended is being used.
The cable is damaged, broken or
smashed.
The connection on the terminal is
loose.
Bad contact of the electrode in the
electrode holder.
The supply voltage to the equipment is
not sufficient.
Any other cause
41
Solution
Improve
protection
against
conditions
Automatic
decreasing the temperature
Replace the potentiometer.
Turn the switch in the ON
position.
Replace the switch.
Replace the fan.
See point 1
Replace the switch.
Replace the electrode with
another one of
diameter.
Replace the cable.
Tighten it.
Remove the eventual oxide
layer from the electrode and
replace it firmly in the
electrode holder.
Find another power source
with
Remove
extension cords from the
power cord, if applicable.
Contact one of our technical
services.
ventilation
recovery
after
smaller
sufficient
capacity.
the
electric