11.10 check pressure readings
Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow.
Check Pressure Readings:
Inlet pressure can be checked by turning screw (A) counter-
clockwise 2 or 3 turns and then placing pressure gauge tubing
over the test point. Gauge should read as described on the chart
below. Check pressure with main burner operating on "HI".
Outlet pressure can be checked the same as above using screw
(B). Gauge should read as described on the chart below. Check
pressure with main burner operating on "HI".
After taking pressure readings, be sure to turn screws
clockwise fi rmly to reseal. Do not overtorque.
Leak test with a soap and water solution.
Prior to pilot adjustment, ensure that the pilot assembly has not been painted. If overspray or painting of
the pilot assembly has occurred remove the paint from the pilot assembly, or replace. Fine emery cloth or a
synthetic scrub pad (such as Scotch-Brite™) can be used to remove the paint from the pilot hood, electrode
and fl ame sensor.
Pressure
Inlet
Outlet

11.11 flame characteristics

It's important to periodically perform a visual check of
the pilot and burner flames. Compare them to the
illustration provided. If any flames appear abnormal,
call a service person.
Tall flame (peak)
52
W415-3091 / B / 03.22.22
Natural Gas
Natural Gas
(inches)
(millibars)
*7"
17.4mb
(minimum 4.5")
(minimum 11.2mb)
3.5"
8.7mb
Low flame (valley)
BL36-1
ODS - MILLIVOLT
B
INSERT PILOT ASSEMBLY
PILOT OUTLET
PSE THERMOCOUPLE
3/8" - 1/2"
(9.5mm - 12.7mm)
Propane
Flame must envelop
(inches)
upper
13"
3/8" to 1/2"
B
(12.7mm - 9.5mm) of
(minimum 11")
(minimum 27.4mb)
thermocouple
10"
*Maximum inlet pressure not to exceed 13"
25.1
SIT ELECTRONIC IGNITION
SORTIE DE PILOTE
3/8" - 1/2"
(9.5mm - 12.7mm)
Flame must envelop
upper
ADD IMAGE
3/8" to 1/2"
(12.7mm - 9.5mm) of
HERE
Flame sensor
Tall flame (peak)
Low flame (valley)
SIT MILLIVOLT
3/8" - 1/2"
(9.5mm - 12.7mm)
Flame must envelop
upper
3/8" to 1/2"
(12.7mm - 9.5mm) of
thermocouple &
thermopile
BL46
PSE LONG SENSOR
3/8" - 1/2"
(9.5mm - 12.7mm)
Flame must envelop