Specifications; Characteristics - Thermolec DCC-12 Manuel D'installation

Masquer les pouces Voir aussi pour DCC-12:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SPECIFICATIONS

Breaker
The DCC – Electric Vehicle Energy Management System (EVEMS) is a
EV charger
60A
70A
safety device with programmable controller that can protect an electrical
30A
distribution circuit in relation with its main breaker. It will prevent
overloading the electrical distribution circuit by turning off momentarily
40A
the power to the charging station when the demand exceeds 80% of the
50A
main breaker rating.
60A
Voltage and wiring
Frequency
Operation temperature
Rated
Wire Gauge Size
Dimensions
*
(H" x W" x D")
Total weight
*
*Approximative and can change without notice.

CHARACTERISTICS

CONDITIONS FOR APPLICATION
The DCC-12 is an Energy Management System specially designed to
allow the connection of an EV Charger, in a house or dwelling, to an
electrical panel that is at full capacity and would otherwise need to have
an expensive service upgrade.
OUTDOOR INSTALLATION
The DCC-12 has a NEMA 3R enclosure approved for indoor and outdoor
installations.
Main power supply
80A
90A
100A
125A
150A
240/208V AC single phase:
L1, L2, Neutral, Ground.
50 à 60 Hz
-22°F à 113°F (-30°C à 45°C)
NEMA 3R
up to 250 kcmil (MCM)
11" x 8" x 5"
8 lb (3,63 kg)
MAIN POWER SUPPLY (CB)
The DCC – Electric Vehicle Energy Management System can be powered
by a 240/208V AC single phase source.
200A
The following options are offered depending on EV charger breaker:
Breaker
EV charger
30A
40A
50A
60A
Voltage and wiring
SECONDARY LOAD SUPPLY (EVC)
The DCC – EVEMS will provide power to a charging station through a
Frequency
30A, 40A, 50A or 60A 240/208V AC circuit breaker, L1, L2 and ground.
Operation temperature
The DCC-12 is NOT equipped with an internal breaker. The breaker to
protect the branch circuit needs to be provided by the installer.
Rated
V2
Wire Gauge Size
TRIP PERCENTAGE (TP)
Dimensions
The DCC - EVEMS is factory set to turn off the charging station if the
total consumption of a service exceeds 80%. For other configurations,
Total weight
please contact the factory.
*Approximative and can change without notice.
POWER OUTAGE
In the event of a power outage, the DCC – EVEMS automatically restore
the power supply to the vehicle charging station when power returns.
RECOVERY TIME (RT)
Following a power cut to the electric vehicle supply equipment (EVSE),
a 15 minutes delay is initiated to monitor the total consumption of the
electrical power system. Power to the vehicle will then be restored if the
total load consumption is lower than 80% of the main circuit breaker
rating during a period exceeding the 15 minutes' recovery time.
Main power supply
60A
70A
80A
90A
240/208V AC single phase:
L1, L2, Neutral, Ground.
50 à 60 Hz
-22°F à 113°F (-30°C à 45°C)
NEMA 3R
up to 250 kcmil (MCM)
11" x 8" x 5"
*
(H" x W" x D")
8 lb (3,63 kg)
*
5
100A
125A
150A
200A
V2

Publicité

Chapitres

Table des Matières
loading

Table des Matières