Cleaning and maintenance

6.12
Replacing the device DC Fuse
➤ Disconnect the power supply to the device.
➤ Pry out the fuse cover (fig. 4 3, page 5) to access the fuse.
➤ Reverse the fuse cover and use the hook to remove the fuse.
➤ Replace the defective fuse with a new fuse of the same type (Automotive Stan-
dard blade fuse, 10 A).
➤ Re-fit the fuse cover.
➤ Reconnect the power supply to the device.
Replacing the DC plug fuse (fig. a, page 10)
6.13
➤ Unscrew the contact pin housing (3) from the plug (1).
➤ Replace the defective fuse (2) with a new fuse of the same type and rating (3AG,
Fast Acting, 10 A).
➤ Re-assemble the plug in reverse order.
6.14

Replacing the light PCB

A
NOTICE! Damage hazard
The lamp can only be replaced by the manufacturer, a service agent or
similarly qualified person to avoid hazard.
7
Cleaning and maintenance
!
WARNING! ELECTROCUTION HAZARD
Failure to obey this warning could result in death or serious injury.
Always disconnect the device from the power supply before you clean
and service it.
A
NOTICE! Damage hazard
• Never clean the cooler under running water or in dish water.
• Do not use abrasive cleaning agents or hard objects during cleaning
as these can damage the cooler.