Jandy
TruClear
Chlorine Generating System
®
™
5.5
BOOST/LOW Mode
The BOOST mode can be used to maximize chlorine
output for a short period of time. To activate BOOST
mode, press the
and
boost will turn off after 24 hours. To turn off BOOST
mode manually, press the
The LOW mode can be used to minimize chlorine output
while activated. To activate LOW mode, press the
buttons simultaneously. The LOW mode will stay on
indefi nitely. To turn off LOW mode, press the
If your Total Hardness
(TH)* level is above
400 ppm or you reside
in an area known to
have hard water,
it is recommended you
change the polarity
reversal time from
the default of 5 hours
to every 3 hours
(instructions on back).
Areas known to have hard water
*Three (3) Total Hardness (TH) test strips are included
Figure 10.
Hard Water Map (Canada)
|
Installation & Operation Manual
buttons simultaneously. The
button.
button
5.6
Polarity Reversal
The Jandy chlorine generating device is a reversible
polarity cell which means that the cell will periodically
switch its polarity to help prevent any build up of
calcium on the cell plates. This is sometimes referred
to as the automated cell cleaning feature. During the
transition between changing its polarity there is a brief
period when the cell will not produce any chlorine.
and
Once it has changed polarity, it will continue to make
chlorine. In areas of hard water (See map in Figure 9).
It is recommended that you manually adjust the polarity
reversal time from 5 hours to three hours. To make
the change, press and hold the up and down arrows
simultaneously to enter the service mode. See Figure 9.
Press the right arrow key once to select "Cyc=". Use the
button to cycle between three, fi ve and seven hour
cycles. Press the
NOTE
'CLEANING' will be displayed on the screen during
the 'WAIT' period. The output level indicator will remain
as set during the cleaning period.
ENGLISH
button to exit.