NOTE The cell must be installed on a 16 Inch (40cm)
horizontal length of pipe after the heaters, pumps,
and filters, as the last piece of equipment in the
circulation plumbing system just before the pool
(see Figure 1).
2.
Remove the existing equipment and make any
appropriate cuts in the pipe where you will be
installing the cell.
3.
Remove the cell from the housing and plumb the
housing into the pipe, making sure that the flow
indicator arrows on the housing match the flow
direction of the water. Pipes must be clean and dry
before gluing.
NOTE If the flow direction of the water does not
match the arrows on the housing, the cell will
malfunction.
|
Installation & Operation Manual
4.
To avoid property damage, serious injury or death, do not
operate the electrolytic cell without water circulation or if
cell housing is damaged or improperly assembled.
3.5
When using electrical products, basic precautions
should always be followed, including the following:
ENGLISH
Let the system dry per instructions provided by the
glue manufacturer. When the glue is dry, start the
system and check for proper water flow. Make sure
the cell is closed (locked into the housing) before
you start the filter pump.
WARNING
Wiring the Power Pack to the Power
Source
WARNING
DANGER: RISK OF ELECTRIC SHOCK WHICH
CAN RESULT IN SERIOUS INJURY OR DEATH.
Before attempting installation or service, ensure
that all power to the device is disconnected/
turned off at the circuit breaker. Connect only
to a circuit protected by a ground-fault circuit
interrupter (GFCI).
Grounding is required. The unit should be
installed by a qualified service representative and
should be properly grounded and bonded (See
Section 3.7, Bonding).
To avoid property damage, serious injury or
death, never use the chassis backplate of the
power pack to ground any other equipment.
Install to permit access for servicing.
Select field conductor size appropriately,
taking into consideration length of circuit and
in accordance with applicable installation
codes. Wiring should only be attempted by a
qualified professional.