STEINEL XLED home curved S Mode D'emploi page 14

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
12� Troubleshooting
Malfunction
Sensor-switched LED floodlight
without power
Sensor-switched LED floodlight
will not switch ON
Sensor-switched LED floodlight
will not switch OFF
Sensor-switched LED floodlight
keeps switching ON and OFF
Sensor-switched LED floodlight
switches ON when it should not
Cause
■ Fuse has tripped, not switched ON,
break in wiring
■ Short circuit
■ Twilight setting in night-time mode
during daytime operation
■ Mains switch OFF
■ Fuse has tripped
■ Detection zone not correctly adjusted
■ Continued movement within the
detection zone
■ Animals moving in detection zone
■ Wind is moving trees and bushes in
the detection zone
■ Cars in the street are detected
■ Sudden temperature changes due
to weather (wind, rain, snow) or air
expelled from fans, open windows.
■ Sensor-switched LED floodlight
swaying (moving), resulting, for
example, from gusts of wind or heavy
precipitation
- 14 -
Remedy
■ Activate, change fuse, turn ON mains
switch, check wiring with voltage tester
■ Check connections
■ Reset
■ Switch ON
■ Activate, change fuse,
check connection if necessary
■ Readjust
■ Check zone and readjust if necessary
or apply shroud
■ Tilt sensor higher or fit shrouds to
target sensor; adjust detection zone or
fit shrouds
■ Change detection zone
■ Change detection zone
■ Adjust detection zone or install in a
different place
■ Fit sensor-switched LED floodlight to a
firm surface

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

6015235

Table des Matières