Hedson DRESTER GP 24 Manuel Technique page 45

Masquer les pouces Voir aussi pour DRESTER GP 24:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.
The upper valve screw should be tightened down
completely and then loosen 1,5 turns. The lower
valve screw should be tightened down completely
and then loosen 6 turns.
4.
The pressure governor should be set to 6 bar. The
intake air regulator should be set to 7.5 bars. To
reset soft start the screw should be tightened down
completely and then loosen 12 turns.
pressure governor
230756 rev 1
upper screw
lower screw
adjusting screw
pressure regulator
5. The lid regulator for cylinder 3 should be set to
2 bars when the lid is closed. Regulator is found
on the terminal box. Open and close four turns.
(Illustrated on picture below)
Open and then close 4 turns.
6. If uncertain connect the calibration kit 230753 to
cylinder 3.
7. Turn OFF the machine.
8. Disconnect the hose to cylinder 3.
9. To connect the calibration kit, remove the red plug
and connect it as seen in the picture.
10. Turn ON the machine. After ~10 seconds the air
pressure value on the calibration kit is stabilized.
EN
air pressure
45

Publicité

Table des Matières
loading