13. Adjustment of solenoid valves
When one or more solenoid valves are changed the flow
restrictors needs to be set properly.
Cyl. 6
4
4
12
Cyl. 5
Cyl. 5
12
10
Tighten the adjustment screw completely, open the
number of turns as indicated in the picture below.
Cyl. 4
Cyl. 4
14
14
12
Open and then close 4 turns.
EN
Cyl. 3
Cyl. 2
13
11
10
Cyl. 1
7