ELEMENTS AND DIMENSIONS....................................................................................................................................................2
DESCRIPTION .............................................................................................................................................................................4
OPERATION ...............................................................................................................................................................................5
OVERVIEW OF THE INSTALLATION: WIRING ...............................................................................................................................7
HOW TO CONNECT THE AUDIO UNIT TO THE KEYPAD PANEL .................................................................................................12
PROGRAMMING INSTRUCTIONS ..............................................................................................................................................13
EXTENDING INSTALLATIONS ....................................................................................................................................................16
INSTALLING AND ADJUSTMENT INSTRUCTIONS .......................................................................................................................17
ENTRANCE PANEL WITH KEYPAD CONFIGURATION INSTRUCTIONS.........................................................................................19
ELECTRONIC DIRECTORY ..........................................................................................................................................................31
ADMINISTRATOR MENU ...........................................................................................................................................................35
TECHNICAL CHARACTERISTICS .................................................................................................................................................37
TROUBLE SHOOTING ...............................................................................................................................................................39
2 - W I R E
D O O R
E N T R Y
S Y S T E M S
2-WIRE DOOR ENTRY SYSTEM

Publicité

Table des Matières
loading

Sommaire des Matières pour Alcad PAK-54010

  • Page 1: Table Des Matières

    2 - W I R E D O O R E N T R Y S Y S T E M S DOOR-VIDEODOOR ENTRY SYSTEMS WITH KEYPAD UNIT 2-WIRE VIDEODOOR ENTRY SYSTEM 2-WIRE DOOR ENTRY SYSTEM INDEX ENTRANCE PANELS: INSIDE MODULES ELEMENTS AND DIMENSIONS..............................2 2-WIRE SYSTEM WITH KEYPAD UNIT DESCRIPTION .....................................4...
  • Page 2: Entrance Panels: Inside Modules

    2 - W I R E D O O R E N T R Y S Y S T E M S ENTRANCE PANELS: INSIDE MODULES - ELEMENTS AND DIMENSIONS - RVE-018 cod.9770054 – + Ctrl2 – Ctrl2 RVE-018 cod.9770054 Inside modules –...
  • Page 3 2 - W I R E D O O R E N T R Y S Y S T E M S iBLACK entrance panel with 2-wire audio unit, generic colour video iBLACK entrance panel with 2-wire audio unit, TFT screen, electronic unit, TFT screen, electronic directory and keypad.
  • Page 4: 2-Wire System With Keypad Unit

    2 - W I R E D O O R E N T R Y S Y S T E M S 2-WIRE SYSTEM WITH KEYPAD UNIT DESCRIPTION - System which makes it possible to perform installations in buildings with one or several points of entry and in compounds containing several inner buildings.
  • Page 5: Operation

    2 - W I R E D O O R E N T R Y S Y S T E M S OPERATION - MAKING A CALL TO A FLAT - To make a call to a dwelling, key in its code on the keypad of the entrance panel. The code which is entered is shown at the top of the entrance panel screen.
  • Page 6 2 - W I R E D O O R E N T R Y S Y S T E M S THE LOOPED AUTO-SWITCH-ON FUNCTION. 2-WIRE VIDEO DOOR ENTRY SYSTEM The auto-switch-on function makes it possible to see the image on the monitor, communicate with the entrance panel and open the door without having received a call.
  • Page 7: Overview Of The Installation: Wiring

    2 - W I R E D O O R E N T R Y S Y S T E M S OVERVIEW OF THE INSTALLATION: WIRING DOOR ENTRY SYSTEM. COMPOUND OF 1 TO 4 BUILDINGS - For distances, number of devices, or types of cable different from those shown in the tables, additional elements may be necessary (e.g. BUS voltage regenerators, signal amplifiers, etc.).
  • Page 8 2 - W I R E D O O R E N T R Y S Y S T E M S DOOR ENTRY SYSTEM. COMPOUND OF 1 TO 4 BUILDINGS For distances, number of devices, or types of cable different from those shown in the tables, additional elements may be necessary (e.g. BUS voltage regenerators, signal amplifiers, etc.).
  • Page 9: Compound, 3 Buildings Of 8 Dwellings Each. 1 External Point Of Entry (Gatehouse)

    2 - W I R E D O O R E N T R Y S Y S T E M S COMPOUND, 3 BUILDINGS OF 8 DWELLINGS EACH. 1 EXTERNAL POINT OF ENTRY (GATEHOUSE) SINGLE-WIRED DIAGRAM B2 B1 B2 B1 B2 B1 DIV-054 DIV-054...
  • Page 10 2 - W I R E D O O R E N T R Y S Y S T E M S REMARKS Identifying the entrance panels of the buildings Assign an identification number to each building, "Housing compound: configuration of entrance panel of building. Keypad panel", page 23. Configuring the external entrance panels Configure the entrance panel of the external access point as an external panel, see see "Housing compound: configuration of the external entrance panel", page 25.
  • Page 11 2 - W I R E D O O R E N T R Y S Y S T E M S COMPOUND, 3 BUILDINGS OF 8 DWELLINGS EACH. 1 EXTERNAL POINT OF ENTRY (GATEHOUSE) WIRING DIAGRAM OF THE EXTERNAL POINT OF ENTRY B2 B1 Building 2.
  • Page 12: How To Connect The Audio Unit To The Keypad Panel

    2 - W I R E D O O R E N T R Y S Y S T E M S HOW TO CONNECT THE AUDIO UNIT TO THE KEYPAD PANEL HOW TO CONNECT Entrance panel Audio unit KPD-521 cod.
  • Page 13: Programming Instructions

    2 - W I R E D O O R E N T R Y S Y S T E M S HOW TO CONNECT THE PANEL WITH DIRECTORY KPD-521 cod. 9650015 RVE-018 cod.9770054 – Ctrl2 Ctrl2 trl2 Permanent lighting Lighting by pressing any key on the entrance panel Lighting of the panel with directory PROGRAMMING INSTRUCTIONS...
  • Page 14 2 - W I R E D O O R E N T R Y S Y S T E M S PROGRAMMING STEPS If the device that you wish to programme is a telephone, begin at step 3. If it is a monitor, begin at step 1. In the case of a monitor: Connect the monitor cable strip in the connections bracket In the case of a monitor: For greater ease, you can lean the monitor against the connections bracket.
  • Page 15 2 - W I R E D O O R E N T R Y S Y S T E M S - PROGRAMMING STEPS - Steps 1 and 2 only when programming a monitor. For telephones, begin at step 3. Maximum time limit Bracket/telephone programmed Maximum time limit...
  • Page 16: Extending Installations

    2 - W I R E D O O R E N T R Y S Y S T E M S EXTENDING INSTALLATIONS Electric lock - Connection - Activation - Standard electric lock Inverse electric lock Power supply for AC electric lock From the dwelling External pushbuttons Power supply...
  • Page 17: Installing And Adjustment Instructions

    2 - W I R E D O O R E N T R Y S Y S T E M S INSTALLING AND ADJUSTMENT INSTRUCTIONS - RECOMMENDATIONS - Before fixing the entrance panel to the pins of the flush-mounted box, put the audio unit in position and make the connections. It is much easier to make the connections in this way.
  • Page 18 2 - W I R E D O O R E N T R Y S Y S T E M S Configure the entrance panel. See "Entrance panel with keypad configuration instructions", page 19. Make the connections between the audio unit and the different elements of the panel (pushbuttons, speaker-microphone module, camera module, etc.).
  • Page 19: Entrance Panel With Keypad Configuration Instructions

    2 - W I R E D O O R E N T R Y S Y S T E M S ENTRANCE PANEL WITH KEYPAD CONFIGURATION INSTRUCTIONS DESCRIPTION - The entrance panel with keyboard and electronic directory leaves the factory with the following characteristics: Ready to use: - In a standard installation (building with a single entrance or access point) - With pre-set operating characteristics (answering time, activation time of electric lock, etc.).
  • Page 20 2 - W I R E D O O R E N T R Y S Y S T E M S Modify factory defaults Installer menu Enter electronic directory STEPS FOR ACCESSING THE INSTALLER MENU With the main screen displayed on the screen, press the keys simultaneously.
  • Page 21: Master Code

    2 - W I R E D O O R E N T R Y S Y S T E M S STEPS FOR ACCESSING THE INSTALLER MENU - Previous Main screen Select Next Maximum time limit MASTER code Error message Código incorrecto Incorrect code Code erroné...
  • Page 22 2 - W I R E D O O R E N T R Y S Y S T E M S CONFIGURATION OF THE ENTRANCE PANEL TYPE OF INSTALLATION AND RANGE OF PROGRAMMING CODES OF TELEPHONES/ CONNECTION BRACKETS If you wish to assign a number between 1 and 9999 to the telephones/connection brackets, or if the panel is going to be working in an installation which is not standard, you will have to reconfigure the entrance panel before programming these devices.
  • Page 23 2 - W I R E D O O R E N T R Y S Y S T E M S ESTATE WITH SEVERAL BUILDINGS WITH PUSH-BUTTONS PANELS Note: For each building, determine the main entrance panel; panel from which the monitors/telephones will be programmed. See "Housing compound: configuration of entrance panel of building.
  • Page 24 2 - W I R E D O O R E N T R Y S Y S T E M S CONFIGURATION OF THE SECONDARY ENTRANCE PANEL (S) Description Default value Value to be chosen Change the value in… Location BUILDING BUILDING...
  • Page 25 2 - W I R E D O O R E N T R Y S Y S T E M S HOUSING COMPOUND: CONFIGURATION OF THE EXTERNAL ENTRANCE PANEL INSTALLATION PARAMETERS Note: If there is only an external panel, it must be configured as the main entrance panel. When there are several external panels, configure one of them as the main panel and the others as secondary panels.
  • Page 26: Operating Parameters

    2 - W I R E D O O R E N T R Y S Y S T E M S OPERATING PARAMETERS Description Default value Change the value in… Call settings Repetitions of the call tone Configuration Call settings Maximum conversation time (seconds) Answering time (seconds) Activation of electric lock...
  • Page 27 2 - W I R E D O O R E N T R Y S Y S T E M S VISITOR: SCREENS SCREEN FLOW Space for text Initial help screen "Initial message" screen Operating mode: Basic Operating mode: Normal Electronic directory "Search"...
  • Page 28 2 - W I R E D O O R E N T R Y S Y S T E M S "INITIAL MESSAGE" SCREEN DESCRIPTION Possibility, with the system in stand-by mode, of displaying an informative text on the screen. This text will be shown on screen, alternating with the initial help screen.
  • Page 29: Main Screen

    2 - W I R E D O O R E N T R Y S Y S T E M S MAIN SCREEN Basic operating mode Shows electronic directory (see on page 31) Normal operating mode Default value Shows help screen Shows the call options (see page 30) Normal operating mode Configuration options...
  • Page 30 2 - W I R E D O O R E N T R Y S Y S T E M S CALL OPTIONS SCREEN Default value Find last name Call by code Shows help screen Description Disable the option in… Search for resident Configuration System...
  • Page 31: Electronic Directory

    2 - W I R E D O O R E N T R Y S Y S T E M S CHANGE THE MASTER CODE - Open the installer menu. See page 20. Select ' Configuration' Select 'System' Select 'MASTER code' Installer menu (page 20) "Configuration"...
  • Page 32 S Y S T E M S STEPS FOR GENERATING THE ELECTRONIC DIRECTORY Use the purpose-made ALCAD software to create the electronic directory on a PC. Transfer the modified file to the root folder of the USB memory stick. Plug the USB memory stick into the USB connector of the entrance panel. This connector is located in the rear part of the panel.
  • Page 33 Remove the USB memory stick. Transfer the file to a PC and modify the information contained in the electronic directory using the purpose-made ALCAD software. Transfer the modified file to the USB memory stick and import it once again into the entrance panel. See page 32.
  • Page 34 2 - W I R E D O O R E N T R Y S Y S T E M S STEPS FOR MODIFYING THE ELECTRONIC DIRECTORY ON A PC "Electronic directory" "USB" "Import/export" Installer menu (page 20) Page 32 "Export"...
  • Page 35: Administrator Menu

    2 - W I R E D O O R E N T R Y S Y S T E M S ADMINISTRATOR MENU DESCRIPTION From the administrator menu, you can only access and modify the following information: name, surname and door-opening code of all residents. The entrance panel leaves the factory with a pre-set ADMINISTRATOR code (factory default ADMINISTRATOR code) which allows you to access this menu, provided that you have enabled this option from the installer menu.
  • Page 36 2 - W I R E D O O R E N T R Y S Y S T E M S STEPS FOR ACCESSING THE ADMINISTRATOR MENU With the main screen displayed on the screen, press the right and left lower keys simultaneously.
  • Page 37: Technical Characteristics

    2 - W I R E D O O R E N T R Y S Y S T E M S TECHNICAL CHARACTERISTICS Note: Reference values are provided only to enable the checking of equipment and are reliable. Do not use the terminals of the equipment to feed additional devices without first consulting the manufacturer.
  • Page 38: Power Supply

    2 - W I R E D O O R E N T R Y S Y S T E M S - TFT CONTROLLER/KEYPAD KPD-521 Voltage POWER SUPPLY Current Operating temperature -...
  • Page 39: Trouble Shooting

    2 - W I R E D O O R E N T R Y S Y S T E M S TROUBLE SHOOTING To program the connection brackets/telephones, make sure that you detected, the audio unit of this panel may be defective. are doing so in the main entrance panel of the building (See "Entrance No monitor/telephone can be heard at the entrance panel panel with keypad configuration instructions", page...
  • Page 40 2 - W I R E D O O R E N T R Y S Y S T E M S...
  • Page 41 2 - W I R E D O O R E N T R Y S Y S T E M S ALCAD Electronics, S.L. Pol. Ind. Arreche-Ugalde, 1 Apdo. 455 | 20305 IRUN - Spain Tel. (+34) 943 63 96 60 www.alcadelectronics.com...

Ce manuel est également adapté pour:

Pdk-54810Pdk-54910Pak-71011Pdk-71711Pak-71012Pdk-71712