A - ENGLISH
OPERATION
1)
Insert the appropriate metering tips into the chemical feed lines (see illustration, page 5).
2)
Fill the holding tank with warm water (not exceeding 120 °F). Do not add any chemical to the tank.
3)
Prepare the area for cleaning by emptying waste receptacles, clearing debris, removing paper products, blowing out vents, and sweeping
fl oors.
4)
Connect the 25 ft power cord (11) to the pig-tail on the rear of the machine. Test the GFCI on the power cord before each use. Plug the GFCI
protected power cord into an outlet.
5)
PRIME THE PUMP: Attach the priming hose to the outlet quick disconnect (D) and place the open end of the hose into the recovery tank.
Turn on the pump and let it run until the pump is completely primed (no visible air in the water stream). Turn the pump off.
NOTE: prime the machine before you place the chemical feed tubes into chemical containers.
6)
Disconnect the priming hose and attach the solution hose (7) to the quick disconnect (D).
7)
Attach the spray gun to the other end of the solution line.
8)
Place chemicals in the molded-in chemical bottle containers (6) on the rear of the machine. Insert one of the feed lines into one of the
chemical containers. Secure the line by screwing on the cap. The chemical will feed from which ever container the selector valve (B) on the
switch plate is turned towards and when the gun is used in the low pressure setting. Use chemicals with a pH of between 4 and 12. Never
add chemicals to the clean water tank.
9)
Set the spray gun (E) to low pressure by sliding the pressure selector forward (low pressure = forward; high pressure = back).
10) Turn on the pump switch (C) (push button) and spray through the gun for a few seconds to fi ll the line with solution.
11) Apply the chemical to the walls and fi xtures from the bottom up. Spray the fl oor last as you work your way out of the room.
12) Allow the chemical to work for the proper amount of dwell time, according to the chemical manufacturer's directions. Agitate heavily soiled
areas with a scrub brush.
13) Turn off the chemical injector valve by turning the selector (B) to the down position.
14) Set the spray gun (E) to high pressure and rinse the area from the top down.
15) Connect the recovery hose (5), attach the squeegee (F), and turn on the vacuum (A) (rocker switch).
16) Squeegee off the mirrors, pick up the liquid off the fl oor with the fl oor tool. If you have the optional blow dry hose, use it to dry the fi xtures.
17) Drain the recovered water into a utility sink or toilet. NOTE: Keep the top of the drain hose (8) higher than the water level in the tank to avoid
uncontrolled discharge of water when you open the cap on the hose.
CAUTION
To avoid vacuum motor damage, always use a defoamer any time foam is present.
Before you turn on the vacuum always make sure the fi lter screen on the ball fl oat is clean and that the ball can travel freely.
RE-PRIMING THE PUMP
If the pump looses prime between jobs, follow the instructions to PRIME THE PUMP, above. If that doesn't get water fl owing, put the priming hose
into the vacuum inlet hose barb and cover the rest of the space around the priming hose with your hand. Turn on the vacuum (with the pump also
running) and let the suction of the vacuum assist in getting water into the pump.
A-6
INSTRUCTIONS FOR USE
TFC 400 - 56380889
revised 1/2012
11/2009