7 TECHNICAL DATA
Technical features (MONOSplit)
Unit
Refrigerant piping
Liquid line
Gas line
Max equivalent length
Max. height difference outdoor unit / indoor unit
Refrigerant pre-charge
GWP
Tons of equivalent CO
2
Additional refrigerant charge
Unit
Electrical connections
Mains power supply (outdoor unit)
Outdoor unit --> indoor
unit connection
Power consumption (outdoor unit + indoor unit)
Rated power input
Rated current input
NOTE:
– at max. pipe length, the yield is approximately 90%
– with a height difference >5m it is advisable to insert a siphon.
28
Signal
Power supply
Cooling
Heating
Cooling
Heating
inches
mm
inches
mm
m
m
kg/m
tco
2
t
t
g/m
V / Hz / p
no.of cables / cross
section
no.of cables / cross
section
no.of cables / cross
section
Nominal (Min~Max)
Nominal (Min~Max)
Nominal (Min~Max)
Nominal (Min~Max)
Technical data
27M
35M
Ø 1/4"
Ø 1/4"
Ø 6.35
Ø 6.35
Ø 3/8"
Ø 3/8"
Ø 9.52
Ø 9.52
25
±10
0.87 / 5
0.87 / 5
675
0.59
0.59
12
27M
230 / 50 / 1
2 x 2.5mm
+ G
2
2 x 1.5mm
2 x 1.5mm
2
2 x 1.5mm
2
+ G
2 x 1.5mm
27M
W
483 (87~1,955)
750 (102~1,955)
W 834 (104~1,955) 943 (104~2,625)
A
2.1 (0.4~8.5)
3.3 (0.4~8.5)
A
3.6 (0.45~8.5)
4.1 (0.45~11.4)
25
±10
675
12
35M
2
2
+ G
35M