The descaling operation is complete when:
the flow of the solution in the hoses at the inlet and outlet of the heating unit is
o
identical, and has no small bubbles at the outlet
AND
the water+descaler solution keeps its initial colour at the outlet
o
Stopping the operation
-
Stop the motor and disconnect the pump
-
Slightly loosen the connection at the pump outlet to let the air enter the circuit and the product
flow into the pump tank.
CAUTION
During this operation, beware any acids which may remain inside the circuit, and which
are likely to drip and damage the floor.
-
When the liquid has bled from the hoses, disconnect the 2 hoses.
-
To neutralise the descaling solution, pour the appropriate Virax neutraliser into the tank, and
dilute according to the indications mentioned on the neutraliser bottle.
-
Empty the tank.
Rinsing the unit
-
In the descaler pump tank which is now empty, dilute the Virax neutraliser with water
(according to the indications mentioned on the neutraliser bottle).
-
Connect the hoses to the heating unit as previously
-
Start the pump and run this solution for a few minutes.
-
Prime the unit and rinse with clean water (20 to 30 litres water) to eliminate any product
residue.
CAUTION
The tank must be empty at all times and cleaned to prevent damaging the motor.

Technical specifications

-
Supply voltage 220V
-
Protection rating: IP 54
-
Maximum operating temperature: 50°C
-
Power: 130 W
-
Flow rate: 40 l./ min
-
Elevation height: 10 m.
-
Tank capacity: 15 litres
-
Delivered with 2 hoses and connections