Petsafe Staywell 500 Série Guide De L'utilisateur page 8

Masquer les pouces Voir aussi pour Staywell 500 Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
Programming the Infra-red cat fl ap
After powering the cat fl ap and the collar key, program your collar key to the
cat fl ap by following these steps:
1. Remove the battery cover by pushing in the direction of the arrows.
2. Press and release the LEARN button (right button).
3. Bring the collar key near the cat fl ap.
4. The LED will fl ash RED, then fl ash GREEN 3 times and then turn off.
5. Your collar key is now programmed to the cat fl ap.
Note: If the LED stops fl ashing red, but doesn't illuminate green, then the
programming was not successful. Check the battery in the collar key and
also check to make sure the collar key is oriented correctly. Then, repeat
the above steps to program the cat fl ap.
Your cat fl ap is now programmed to recognise the collar key and the latch
mechanism will be activated every time you approach the cat fl ap with the
collar key. (Fig. 16). The latch will not relock until the collar key is out of
range of the cat fl ap.
Note: The latch on your cat fl ap has been
factory set to re-latch after 3 seconds.
The colour codes available are:
Green,
Yellow, Blue, and Pink.
Extra keys can be
purchased from the Staywell
®
website -
www.staywell.co.uk
MANUAL
8
Programming the Infra-red cat fl ap
for additional cats
If you have more than one cat, you will need to purchase additional
collar keys. If you use the same coloured collar keys as you originally
purchased, no further programming will be required. However, if you
prefer to use different coloured collar keys (Green, Yellow, Blue, or Pink),
you will need to program each collar key to the cat fl ap. All four collar
keys can be programmed to the cat fl ap. Follow the above steps for
programming each collar key.
Erasing programmed collar keys from
the cat fl ap memory
If it becomes necessary to change the collar keys used with the cat fl ap
FIG.16
(i.e. discontinue use of a certain colour), you will fi rst need to delete all of
the original coloured collar keys from the cat fl ap memory.
1. Remove the battery cover by pressing in the direction of the arrows.
2. Press and release BOTH of the buttons.
3. The LED will fl ash RED for 2 seconds.
4. The cat fl ap memory has been erased.
Refer to the steps above for programming new collar keys to the cat fl ap.
LEARN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

500 sérieStaywell deluxe

Table des Matières