Troubleshooting and customer service

The unit has been manufactured using state-of-the-art production methods and tested several times to
ensure its correct function. If malfunctions should occur, please check the unit as detailed in the list below. If
all functional checks have been carried out and the device still fails to operate properly, then please notify
your nearest specialist dealer.
Functional trouble
Fault description
The unit does not start
The unit is running with Reduced
ventilation output
Condensate leaks out of the unit
Error codes
Error codes
Fault description / note
01
I/O PCBA error communication
02
Air intake sensor defective
03
Evaporator sensor defective
32
Liquid line sensor defective
33
Hot gas sensor compressor defective
35
Compressor speed is not correct
36
Compressor over temperature
37
Liquid line heat exchanger is too high
B-18
Cause
Mains failure
Mains fuse or controller fuse
faulty
Mains plug not inserted in
socket
Condensate container full,
display "DRAIN WATER"
flashes
Timer mode active
Used air or outlet openings
soiled or blocked by foreign
bodies
Filter soiled
Outdoor unit soiled
Cooling load of the room
excessive
Device standing at an angle
Plugs missing from conden-
sate drain hose
Remedy
Check voltage and if necessary wait
until power is back on
Arrange to have exchanged
Insert mains plug
Empty container via condensate drain
hose
Wait for timer period to expire or press
"I / 0" button again
Clean the openings Remove foreign
bodies
Clean the filter in accordance with the
instructions
Clean the fins on the inside of the out-
door unit
Reduce the thermal load
Position vertically, ensure stable posi-
tioning
Seal the hose so that it is watertight
again