Trotec PAC 4600 Manuel D'utilisation page 37

Masquer les pouces Voir aussi pour PAC 4600:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

20 cm
Fig. 10: Max. assembly height
External wall mounting with fastening straps
Fastening straps are an additional option for
mounting the outdoor unit to an external wall or
parapet wall.
n
Hook the wall bracket onto the outdoor unit and
secure it with the screws (M4).
n
Hook one end of the fastening strap with the
spring catch into the fastening eyelet of the
outdoor unit.
n
Hook the other end of the fastening strap into
the eyelet bolt which is to be attached to the
on-site external wall or parapet wall (Fig. 11).
Ensure sufficient stability.
NOTICE!
Depending on weather conditions it is possible
that condensate will run out of the condensate
drain on the rear of the outdoor unit. This is a
normal process. Select the installation site for
the outdoor unit in such a way as the draining
water cannot cause any form of damage or
hook up the connection to a drain.
1
2
3
Fig. 11: Assembly with fastening straps
1
Spring catch
2
Fastening eyelet
3
Safety bolt M4
4
Eyebolt
4
B-13