3. Start-up
See Instructions for Use of the filter and blower device to be used.
With a compressed air line device see Instructions for Use of T/A/LINE, and use breathing hose T/Pcap
Caution! Some materials which come into contact with the skin may cause allergic reactions in particularly
susceptible individuals.
Caution! The face shield/welding shield must be kept on the face always when working in a hazardous area.
Check before use
intactness of helmet, face shield and breathing hose.
face seal correctly affixed to the visor frame at all points.
intactness and position of brow seal.
Fix the breathing hose tightly to the hose socket of the helmet and close the locking latch.
Fix the breathing hose tightly to the blower device.
Screw the filters tightly to the blower device.
Visor
Remove eventual protective film from both visor surfaces.
Check that the visor is intact (scratches).
Check that the visor shade is correct for the intended work.
Caution! The golden visor does not provide adequate protection at welding.
Welding filter
Welding filters are standard 110x90 mm size.
Check that the welding filter shade is correct for the intended work.
Check that the fenestra is intact (distortion).
Check that the welding filters fit into the fenestra and the fenestra sits into the welding shield without leaving
gaps (light leak).
Caution! If the welding filter is made of mineral reinforced material (e.g. glass), it must be supplemented with
a separate protective lens (e.g. 064497
Head harness
Adjust the head harness to get a good fit (and the visor comes in front of the eyes):
Wearing hight: with the horizontal openings in the crown strap ends. The size and
shape of the head or the use of accessories may require that the headband is adjusted
deeper for a correct fit.
Head size: with the ratchet knob (handwheel) at the back of the headband. For sizes
53 – 65 cm.
Face seal
Adjust the face seal tension by placing its uppermost (yellow) pins to either of the
brow seal holes (located at the two extensions).
Fix eventual hearing protector to the helmet. Check adequate attenuation.
Donning
Don the blower device, then check adequate air flow (see Instructions for Use of the blower unit).
Don the Procap so that the visor is placed in front of your eyes and the breathing hose trails freely down the
back and is not kinked or looped.
Arrange the face seal under the chin and around the cheeks.
Check that hair or clothing is not trapped in the seal.

After use

Doff the Procap and carry out the necessary maintenance for the helmet and blower device (see respektive
instructions). Replace worn-out filters of the blower device (all filters at the same time).

4. Maintenance and storage

Store protected from direct sunlight, at -10 °C...+50 °C, relative humidity (RH) under 75 %.
A properly stored, unused face shield stays in good condition for a long storage period.
Clean with a damp cloth or sponge, using lukewarm water and mild detergent (neutral, pH 6-8) (e.g. washing-
up liquid) (be careful not to scratch the visor). Do not wash under running water, keep water away from the
airduct and hose.
Do not use solvents (e.g. acetone, turpentine), hot water or bleaching agents (perborate, percarbonate).
Never clean with compressed air or compressed water.
Maintenance of the blower units is described in the respective Instructions for Use.
Procap is coarse waste. A very contaminated mask as well as used filters are special refuse and shall be
disposed of according to the filtered substances (gases or particles).
).
anti-spatter lens