Electrical Connection - Suevia 500 Mode D'emploi

Publicité

Les langues disponibles

Les langues disponibles

Fixation on tubes 1¼" - 2"
1¼" - 2"
101.0179
76
76
315
101.0179
Regulation of the valve
Valve bar
1
3
4
5
2
Flap
Mounting of the valve heating 131.0527
4
Fixation
The SUEVIA Valve Trough Drinker Mod. 500 can be fixed either on vertical or horizontal tubes 1¼" - 2",
as well as on the wall. Wall fixation with a Fixation angle 90°, galvanized Ref. 131.1050 possible (see
Cover
accessories). For tube fixation 2x SUEVIA Double Brackets Ref. 101.0179, are required.
Recommended Installation Height
90 - 100 cm / 36" - 40" until edge of trough
Water connection
225
By means of a lateral ¾" connection angle (not incluced) water connection can be done from the top or
bottom. For the connection of the water tube SUEVIA Boring Bracket Ref. 101.0535 is foreseen.
Pipe union is recommended. In case of risk of frost insulate water line and maintain frost-free by means of
a frost protection heating cable.
90 -
Attention!
100 cm
Flush water line well before you connect Mod. 500! If dirty water (sand, suspended matters) is given,
SUEVIA preliminary filter Ref. 101.0487 must be installed before the trough drinker. Consider the norm DIN
1988 / DIN EN 1717!
Water pressure
The valve is suited for high and low water pressure.
Minimum water pressure 0,5 bar, max. 5 bar. / Minimum water pressure 7,25 psi, max. 73 psi.
Regulation Screws
Water flow approx. 30 l/min. given 5 bar. / Water flow approx. 7,9 gal/min. given 73 psi.
Regulation of the valve
• (Pos. 1) Unscrew 6-edges fixation screw at middle of the top cover. Take off the cover 132.0505.
• (Pos. 2) Untighten the nuts 102.0254 located on both sides of the drinker.
• (Pos. 3) Move the counter weight towards the valve connection
• Let the water flow at high pressure
• (Pos. 3) If the valve is not tight, the counter weight has to be pushed slightly away from connections
untill the valve is tight.
6
• (Pos. 4) Add 2 cm as a security-distance (away from the valve).
• (Pos. 5) Screw the counter weight.
• (Pos. 6) Check that the distance between the non-operated counter weight and the flap is 1 cm. If
needed adjust the bar in a new position by untightening regulation screws. Afterwards control the tight
fixation of the regulation screws.
Junction box
* Not included in the scope of delivery of Mod. 500!
Max. cable lengths
Section e.g.: Type NYY
2,5 mm²
4,0 mm²
6,0 mm²
Guidelines. Please note cable data sheets and local standards.

Electrical connection

101.0389
101.0389
IP54
IP44
230 V
Transformer
24 V
till 100 Watt
83 m
132 m
200 m
131.0523
131.0523
101.0861 - 24 V / 20 W
101.0861 - 24 V / 20 W
101.1863 - 24 V / 30 W
101.1863 - 24 V / 30 W
till 200 Watt
till 300 Watt
42 m
28 m
66 m
44 m
100 m
66 m
131.0527
131.0527
till 400 Watt
21 m
33 m
50 m