Technical description

5
Technical description
A
NOTICE!
Operator must know local regulations for emptying a holding tank.
5.1
Probe assembly with float switch
The probe assembly installs into a 32 mm diameter opening on the top of a Dometic
holding tank or other holding tank. As the level of holding tank contents rises, the
float switch inside the tank is pushed upward and activates the "Full Tank" light on
the indicator panel.
5.2

Indicator panel

The indicator panel has a single light which is activated by the float switch inside the
holding tank. When the "Full Tank" light is activated, the operation of any plumbing
fixture connected to the holding tank should stop until the tank is emptied.
6

Installation

6.1
Overview
For general installation layout see fig. 2, page 3.
Wiring diagram: fig. 3, page 3.
Key to Wiring diagram
Item
Description
1
Float switch
2
Indicator panel
bl
Blue
rt
Red
sw
Black
ws
White
Indicator panel template: fig. 8, page 5.