NSTALLATION DETAILS
Horizontal ceiling mount
Inclined ceiling mount
• The ideal mounting position is directly above the area to
be heated with a longitudinal orientation and facing
vertically downwards.
WARNING:
The heater must never be installed in the upwards or
inwards facing position, the heating surface must always be
positioned to direct the heat in a downwards or outwards
direction.

Correct Installation

CEILING
• Find below the minimum clearances when mounting the
heater parallel with a ceiling. (Unit in mm)
Fans, lights and
sprinkler fittings
MUST NOT
be below heater
1000 mm minimum to surface
(ie table tops, etc)
2100 min. from floor
3000 mm max. from floor
(recommended)
• Find below the minimum clearances when mounting the
heater at an angle to the ceiling. (Unit in mm)
Fans, lights and
sprinkler fittings
MUST NOT
be below heater
1000 mm minimum to surface
(ie table tops, etc)
2100 min. from floor
3000 mm max. from floor
(recommended)
• Find below the right wall mounting position. (Unit in mm)
Correct Installation
CEILING
Angled horizontal ceiling mount
Incorrect Installation
CEILING
CEILING
Same on both
ends
Same on both
ends
Fans, lights and
sprinkler fittings
MUST NOT
be below heater
1000 mm minimum to surface
(ie table tops, etc)
2100 min. from floor
3000 mm max. from floor
(recommended)
WARNING:
Mounting of the infrared heater and its connection to
the electric mains should be carried out only by
qualified specialists according to the Electrical
Installation Regulations and Power System Safety
Standards.
I
P
:
NSTALLATION
ROCESS
1. Open the factory package and carefully take the heater
out.
2. Take out the packing paper sheet from the end of heater.
3. Take out one pair of mounting Brackets. These adjustable
brackets allow direct ceiling or wall mount, and come with
preset angle options of parallel, 15°, 30°, 45° and height
170mm.
4. The correct installation process, as per the diagram
above, select the heater location on the ceiling by locating
the stud or structural beams to ensure secure fastening of
the heater, whilst observing the minimum clearances from
the floor and other objections.
5. Install two brackets on the ceiling or wall with the
following minimum recommended bracket distance "B".
6. Set the adjustable angle mounting brackets to desired
angle and fasten brackets by spanner.
GB
Same on both
ends
170mm