Servicing Instructions; Electrical Supply - Baxi luna 3 comfort Notice D'emploi

Masquer les pouces Voir aussi pour luna 3 comfort:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

eRRoR
Description of Faults
coDe
01e
Gas supply fault
0e
Safety thermostat sensor tripped
03e
Flue thermostat sensor tripped / Flue pressure switch
tripped
04e
Safety error for frequently loss of flame
05e
Central heating NTC sensor fault
06e
Domestic Hot Water NTC sensor fault
10e
Water pressure LOW
11e
Safety thermostat has cuts out (for low temperature
system)
5e
Boiler max temperature exceeded
(probable pump jammed or air in the circuit)
31e
No communication between the main board and the
remote temperature control
35e
Fault flame (parasitic flame)
80e
Internal remote control error
97e
Wrong power supply electrical frequency (Hz)
98e
Electrical main board internal error
99e
Electrical main board internal error
To maintain efficient and safe operation of your boiler have it checked by a Qualified Service Engineer at the end of every
operating period.
Careful servicing will ensure economical operation of the system.
Do not clean the outer casing of the appliance with abrasive, aggressive and/or easily flammable cleaners (i.e.: gasoline,
alcohol, and so on). Always isolate the electrical supply to the appliance before cleaning it (see section 6).
The boiler requires a 120 V 60 Hz supply.
tHe applIance Must Be GRounDeD.
BaxI - 95.187.1

10. servicing instructions

11. electrical supply

13
coRRectIve actIon
Press the oK button (figure 1) for at least 2 seconds. If this
fault persist, call an authorised Service centre.
Press the oK button (figure 1) for at least 2 seconds. If this
fault persist, call an authorised Service centre.
Call an authorised Service centre.
Call an authorised Service centre.
Call an authorised Service centre.
Call an authorised Service centre.
Check that the pressure in the system is as specified. See
Section 5. If this fault persist, call an authorised Service
centre.
Call an authorized Service centre.
Call an authorized Service centre.
Press the oK button (figure 1) for at least 2 seconds. If this
fault persists, call an authorized Service centre
Press the oK button (figure 1) for at least 2 seconds. If this
fault persists, call an authorized Service centre
Call an authorized Service centre.
Set the correctly electrical frequency (Hz)
Call an authorized Service centre.
Call an authorized Service centre.
InstRuctIons peRtaInInG to tHe useR
GB
FR

Hide quick links:

Publicité

Chapitres

Table des Matières
loading

Table des Matières