WaRnInG: do not press any button after having enabled this function. By pressing some of the remote control buttons, it
is possible that the manual function is enabled by mistake (in this case the display shows the
the "Holiday Program" function shut off . In this case it is necessary to repeat the instructions described at the beginning
of this section to enable again the function.
4.4. paRty function
This function allows the user to set a temporary room temperature value. It is possible to change this temperature value
also during the function operation.
The operating mode returns to a previews setting at the end of this period of time.
To enable the function, proceed as follows:
•
press the
button to set the function to "Manual" (symbol
•
press the
button, the display shows the writing MM 60 and the
•
to set the period of the timing program see the section 4.4.1.
•
to modify the room temperature value, press the "OK" button (the display shows "aMB") then press the +/-
buttons.
The system design pressure (cold) should be set to (7.25-14.5) p.s.i. / (0.5-1) bar. This pressure is equivalent to the maxi-
mum static head in bar + 0.3 (14.5 p.s.i. = 1 bar = 10.2 metres of water).
Filling of the system must be carried out in a manner approved by the local Water Undertaking. The system may be filled
as shown in Fig. 3.
Drain taps must be used to allow the system to be completely drained.
The heating system should be thoroughly flushed before the boiler is connected and again after the first heating.
IMpoRtant: Regularly check that the pressure displayed by the pressostat (figure 3) is 0.5 to 1.0 bar (7.25-14.5 p.s.i.)
with boiler not operating. In case of overpressure, open the boiler drain valve (figure 3).
In case the pressure is lower open the boiler filling tap (figure 3).
We recommend you open the tap very slowly in order to let off the air.
During this operation, the gas boiler must be in "OFF" mode (press the
note: In case pressure drops occur frequently have the boiler checked by a Qualified service engineer.
310 Fi
Figure 3a
BaxI - 95.187.1
5. filling the boiler
Filling tap
Manometer
Drain point
11
);
flashing;
- figure 1).
1.310 Fi
Figure 3b
InstRuctIons peRtaInInG to tHe useR
symbol) and that causes
Boiler filling tap
GB