c. Squeeze bulb retainer where indicated, grip white socket and slide bulb out sideways.
d. Grip white socket and, working back and forth, pull socket from bulb pins.
e. Repeat for second bulb. Always replace both bulbs at the same time.
Be sure the power is OFF before installing or removing lamp. Allow the lamp to cool before relamping. This light fixture uses a
quartz Halogen lamp. DO NOT touch the lamp with bare hands: This may severely reduce its life. Use the plastic furnished with
the replacement, a clean rag, or a tissue to eliminate fingerprints from getting on the lamp.
5. Install the new lamp(s).
a. Push bulbs into white socket.
b. Squeeze copper bulb retainer and slide bulb in from
side.
c. Ensure bulb is tight against copper plate between
locating guide bumps.
6. Remove old gasket from lens and discard it.
7. Swing color wheel/bulb assembly back into position over 4
fixture studs. Secure with 4 nuts. Do not over tighten.
8. Install new gasket during reassembly of light, Pentair Pool
Products' part number 79101600.
Never operate the underwater light for more than 10 seconds unless
it is totally submerged in water. Without total submersion, the light
assembly will get extremely hot and may result in serious burns or in
breakage of the lamp or lens. This may result in serious injury to pool
users, installers, or bystanders, or in damage to property.
9. Align the special pilot screw on the face ring with the
letter "O" of the word "TOP" on the surface of the lens.
The pilot screw, "O" in "TOP" and the white pointer on the color wheel/bulb assembly should also align with the
cord compression fitting on the top rear of the light fixture.
10. Align the special pilot screw on the face ring with the letter "O" of the word "TOP" on the surface of the lens.
The pilot screw, "O" in "TOP" and the white pointer on the color wheel/bulb assembly should also align with the
cord compression fitting on the top rear of the light fixture.
11. Secure ring to light fixture. See Section VI., Stainless Steel Face Ring Assembly Instructions.
12. Replace light assembly into niche and tighten special pilot screw.
Use only the special pilot screw provided with this underwater light. This screw mounts and electrically grounds the housing
securely to the mounting ring and wet niche. Failure to use the screw provided could create an electrical hazard which could
result in death or serious injury to pool users, installers or others due to electrical shock.
13. Fill pool until the underwater light is completely submerged in water before operating the light for more than 10
seconds. Turn on main switch or circuit breaker, as well as the switch which operates the underwater light itself,
to check for proper operation. Refer to Operating Instructions, Section IV., for full function test.
P/N • Núm/Pte. • Réf. P/N 619408
WARNING
WARNING
WARNING
6
Copper Lamp Retainer
Bulbs (2)
Figure 3.
Rev. A • Rev. A • Rév. A 6-5-01