Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
Do not allow the streams of the shower touch sensi-
tive body parts (such as your eyes). An adequate
distance must be kept between the shower and you.
The product may not be used as a holding handle. A
separate handle must be installed.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
Shower hoses are only suitable for a connection
from the shower to the fitting. Never fit a shut-off
device between the fitting and the hose.

Installation Instructions

The fitting must be installed, flushed and tested after
the valid norms.
Where the contractor mounts the product, he should
ensure that the entire area of the wall to which the
mounting plate is to be fitted, is flat (no projecting
joints or tiles sticking out), that the structure of the wall
is suitable for the installation of the product and has
no weak points. The enclosed screws and dowels are
only suitable for concrete. For another wall construc-
tions the manufacturer's indications of the dowel
manufacturer have to be taken into account.
The filter insert (97708000) must be used to ensure
the standard flow rate and to protect the hand
shower against incoming dirt by pipework. Do you
want a larger water flow rate, then you must use the
filter packing (94246000) instead of the filter insert
(97708000). Incoming dirt leads to defects or/and
can damage parts of the hand shower; such caused
faults voids all liability and guarantee claims.
The wall bar must be mounted stress relieved!
Optimal functioning is only guaranteed with the com-
bination of Hansgrohe hand showers and Hansgrohe
shower hoses.
Assembly
27636XXX/27893000/27658000
see page 34
4
English
Technical Data
Operating pressure:
Recommended operating pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Symbol description
Do not use silicone containing acetic acid!
With the excentric washer it is possible to
equalize tolerance of the drilling. (see page
35 + 37)
Dimensions (see page 31 - 33)

Flow diagram

(see page 32)
Operation (see page 39 - 40)
Cleaning (see page 41) enclosed
brochure
Spare parts (see page 42)
Special accessories
corner fitting set (28694000) order as an
extra
Test certificate (see page 43)
27637000/27638000
Assembly
see page 36
max. 0,6 MPa
0,1 - 0,4 MPa
max. 60°C