Installation

Installation- Ducting version
After having chosen the vent option, proceed as follows:
Prepare duct and conduit cut outs as needed.
If possible, disconnect and move freestanding or slide-in range
from cabinet opening to provide easier access to rear wall.
Otherwise put a thick, protective covering over countertop, cook-
top or range to protect from damage and debris. Select a flat sur-
face for assembling the unit. Cover that surface with a protective
covering and place all canopy hood parts and hardware in it.
Determine and mark the centerline on the wall where the
canopy hood will be installed. Select a mounting height comfort-
able for the user and mark on wall.
Prepare duct and conduit cut outs as needed.
Remove the duct knockouts using a flat blade screwdriver and a
small hammer.
Use the screwdriver by knocking out the panel in similar fashion to
a scalpel.
Take care of sharp edges.
Vertical
discharge
Attach exhaust adaptor/damper over knockout opening with four
exhaust adaptor screws. Make sure damper pivot is nearest to top/
back edge of hood.
Remove tape from damper flap.
NOTE: The exhaust adaptor/damper can be installed up to 1 inch on
either side of the hood center to accommodate offcenter ductwork.
In extreme offcenter installations, one end of the duct connector may
need to be trimmed to clear the electrical cable clamp.
Exhaust
transition/damper
Pivot
Horizontal
discharge
Top/back
edge
Top/back
edge
Exhaust
Pivot
transition/damper
Mark holes
Select the vent option that your installation will require and proceed to
that section:
Outside top exhaust
(Vertical duct– 3
"x 10" Rectangular)
1
4
Use the diagram or the hood as a template and mark the locations on
the cabinet for ductwork, electrical wiring and keyhole screw slots.
30" model: 6
" (16.2cm)
3
8
36" model: 8
" (22.2cm)
3
4
"
13
32
(1 cm)
7
"
1
2
(19 cm)
7
"
7
8
(20 cm)
2
"
1
2
(6.3 cm)
Wiring access knockout
(cabinet bottom side)
For recessed bottom cabinet only
If the cabinets have front, side or back trim, make 2 wood shims the
width of the trim and attach them to the cabinet bottom recess on both
sides.
Wood shims
Outside rear exhaust
(Horizontal duct– 3
"x 10" Rectangular)
1
4
Use the diagram or the hood as a template and mark the locations on
the cabinet for ductwork, electrical wiring and keyhole screw slots
30": 13
" (35.15 cm)
13
16
36": 16
" (42.77 cm)
13
16
"
9
16
(1.4 cm)
7" (17.7 cm)
3"
(7.6 cm)
10
5
8
Permanent
Mounting hole
Remove the grease filters.
Remove the blower mounting screws.
7
Cabinet
front side
Cabinet
bottom side
5
"
5
"
1
1
4
4
(13.3cm)
(13.3cm)
3
"
1
Vent system hole
2
(8.9cm)
CENTER
" (1.58 cm)
5
8
LINE
WALL
30": 13
" (35.15 cm)
13
16
36": 16
" (42.77 cm)
13
16
7" (17.7 cm)
" (27 cm)
10
" (27 cm)
5
8
CENTER LINE
Mounting
screws (4)
Vent
shims
"
9
16
(1.4 cm)