Operating the generator
Display message
Description
GENERATOR ALERT!
General alarm message
Example: The control ring on the
throttle valve of the carburettor
(stepper motor) is faulty.
OVERLOAD!
The consumers generate an
overload at the output.
SHORT CIRCUIT
The consumers cause a short cir-
cuit at the output.
OVER TEMPERATURE
Overheating
LOW POWER ENGINE
The inverter supply voltage has
dropped.
Overspeed
RPM too high
Start failed
Example: No fuel, cold tempera-
ture, spark plug to be replaced,
dirty air filter
GEN CAL
Message appears when the gen-
erator is started up; it shows the
calibration phase which takes
place before each start-up. The
generator does not supply any
voltage.
18
Generator behaviour
The generator stops.
The inverter switches off, there-
fore no voltage is supplied but
the engine carries on running
until it goes off.
The inverter switches off, there-
fore no voltage is supplied but
the engine carries on running
until it goes off.
The inverter switches off so no
voltage is supplied to cool the
generator, but the engine car-
ries on running.
The generator stops.
The generator stops.
The generator is switched off.
The generator is running but
does not supply any voltage.
TEC60, TEC60LPG
Measures
Check the system by referring to
the troubleshooting table.
If the problem persists, contact
the manufacturer's branch office
in your country (addresses on the
back page).
Reduce the connected load and
start the generator again.
Check the connected consum-
ers then start the generator
again.
Leave the engine to cool down
for a few minutes then start the
generator again.
Reduce the connected load and
start the generator again.
Press the button START/STOP to
restart the generator. If the prob-
lem persists, contact the manu-
facturer's branch office in your
country (addresses on the back
page).
Press the start button to restart
the generator.
Wait a moment.
EN