Télécharger Imprimer la page

Ingersoll Rand ARO 651763 Série Manuel D'utilisation page 25

Publicité

Les langues disponibles

Les langues disponibles

c. Manual Mode
On the Run Modes Selection screen, select "Manual" to be taken to the Manual mode start screen.
To start the pump select "Begin Run" and press ENTER or the START/PAUSE button.
To exit this screen without starting the pump press either "NAVIGATE TO PREVIOUS" or "NAVIGATE TO HOME".
While the pump is running the screen displays the actual flow rate.
The pump flow or cycle rate can be adjusted while the pump is running. To adjust, press ENTER and type the new
value, or press the LEFT / RIGHT buttons to decrease / increase the flow or cycle rate, respectively. Pump speed
will vary in steps of 5 cycles per minute (or the calculated equivalent in the units selected), per keystroke.
Notice: That the pump status has changed to "Running".
d. Auto Fill Functionality
The controller can receive signals from a container to indicate if it is empty or full.
When a "tank full" signal is received, the pump pauses, and the screen shown is displayed.
Because the pump is paused, calibration and batch tallies are not lost.
The pump will remain paused until the "full tank" input disappears, and either the START/PAUSE button is
pressed, the "Start Pump" selection is made from the screen and ENTER pressed, or the "tank empty" input signal
is received.
The auto fill functionality is always active, in any of the pump operational modes. To disable this feature, no signals shall be wired into the
controller.
e. General Notes on Pump Running
It is possible to navigate to other screens and execute multiple actions while the pump is running. However, it is
not possible to change the program being executed, although other programs can be changed.
It is not possible to start another program, or restart the current program while the pump is running. The shown
error message will be displayed. It is necessary first to stop the pump
If the (external) emergency stop is activated, all pumps will stop and the error message shown is displayed.
When the emergency stop is cleared, the screen returns to the home screen.
3. Software Update
Before attempting to update the software, verify the version currently loaded, see section 1.a.
47520296001_edD
To perform the actual controller software update, procure a USB cable with a USB type B connector on
one end (to connect to the controller) and a USB type A connector on the opposite end (to connect to the
computer). This cable is not supplied with the controller.
EN
EN-8

Publicité

loading