Troubleshooting

The following table should help you diagnose most problems that may arise when using the AVR200.
Problem
Cause
No audio
1. Power Lead unplugged or not switched on
2. In stand by mode
3. Mute on
4. Tape monitor selected
No sound on one
1. Loudspeaker not connected or not connected properly
channel
2. Input not connected or not connected properly
3. Speaker described as 'OFF' in set up page
4. Channel level set too low
Dolby Digital or DTS not
Digital input not connected
auto detected
Lack of bass or poor
1. Speakers wired out of phase (i.e. + connected to –, or red
stereo image
to black in error – a polarity error in one speaker)
2. Speakers set as 'SMALL'
No sound from tuner
1. Aerial not connected properly
2. Weak signal muted by FM Mute
Remote control not
1. Batteries in handset fi tted the wrong way round or fl at
working
2. IR receiver window on AVR200 is obscured
3. IR receiver window fl ooded with light
Picture scrolls around
Wrong video system selected
screen, or picture is
only in black and white
No picture on monitor
1. Source is not playing
when video source is
2. Video connection between the source and AVR200 is not
selected
been made
Sound and picture
System connections made to wrong inputs of AVR200
come from different
sources
AVR200 switches itself
Circuits have overheated and unit has been switched into
to stand by mode
protection mode. This may be because airfl ow around the
unit is restricted.
The red status LED
The AVR200 has gone into protection mode. This is
fl ashes and the AVR200
probably caused by an overload or short circuit on the
appears not to work.
loudspeaker outputs.
Solution
1. Check mains lead is connected to AVR200 and that the wall
switch is on
2. Press the
button on remote handset
POWER/STANDBY
3. Switch mute off
4. Press the
button
TAPE MONITOR
1. Check connections to AVR200 and to loudspeaker
2. Check connections to AVR200 and at source
3. Re-assign speaker settings in on-screen display
4. Re-assign channel balance in on-screen display
Connect digital output of source to appropriate input on
AVR200
1. Check all connections to AVR200 and to loudspeakers
2. Re-select preset speaker settings in on-screen display
1. Check aerial connections to AVR200's back panel
2. Switch
off or re-tune station
FM MUTE/MONO
1. Check orientation of batteries/ replace discharged batteries
2. Remove obstruction
3. Move AVR200 away from light source or shade from intense
light source
To toggle between PAL and NTSC video systems, press and
hold the
button and click the
STORE
1. Check and play source
2. Check system wiring: ensure connection between source
Check system wiring: ensure all connections are made to
correct input on AVR200
Switch unit off. Remove any restrictions to good airfl ow. Allow
unit to cool down before switching on again.
1. Turn the AVR200 off and disconnect the mains cable.
2. Check all the wiring, making sure that no bare loudspeaker
cables are touching each other or the chassis.
3. Reconnect the mains cable and switch back on.