MENU
Enables or disables automatic closing
TCA
On: automatic closing enabled
Off: automatic closing disabled
Enables or disables multi-flat function.
On: multi-flat function enabled. The step-by-step and perdestrian commands have no effect
IBL
during the opening phase.
Off: multi-flat function disabled.
During the TCA phase, the PP controls are enabled or disabled.
IBCA
On: PP controls are disabled.
Off: PP controls are enabled.
The rapid closure is enabled or disabled. It can be activated only if TCA:ON
On: enabled rapid closure. With open gate, the photocell activation causes the automatic
closure after 3 s.
SCL
If the photocell is activated during the opening phase, the operation is completed and
closure starts after 3s
Off: disabled rapid closure.
The operating mode of "P.P. Push button" and of the transmitter are selected.
PP
On: Operation : OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Forewarning flashing light enabled or disabled.
PRE
On: enabled forewarning flashing light. The flashing light is activated 3 s before the starting of the motor.
Off: disabled forewarning flashing light.
The Service Man function is enabled or disabled.
On: Service Man operation. The OPEN/CLOSE push buttons should be kept pressed for the
HTR
entire operating time.
Off: Automatic operation.
During the TCA time, the blinker is enabled or disabled.
LTCA
On: Enables blinker.
Off: Disables blinker.
The PHOT O input is enabled or disabled in the opening phase.
Pho1
On: Photocell 1 activated only in the closing phase.
Off: Photocell 1 activated in both opening and closing phases.
The PHOT C input is enabled or disabled in the opening phase.
Pho2
On: Photocell 1 activated only in the closing phase.
Off: Photocell 1 activated in both opening and closing phases.
The check on the photocell connected to PHOTO input is activated or deactivated
Before operation, the control unit checks the switching of the photocell contact.
The test shall be carried out following any command (PP, OPEN, CLOSE, radio, TCA) with engine
off before performing the manoeuvre (even partial manoeuvres). The test is not carried out when
tst1
the engine already in motion must stop and then reverse following the SAFETY EDGE or PHOT
intervention. If the checks are not successful, the door/gate will not move.
On: activated check on photocell.
Off: deactivated check on photocell.
tst2
As for TST1, but referred to PHOTC input
It changes the mode of operation of the PHOTO inputs (photocell in OPEN) and BAR in case
the sensitive safety edges are installed in the mobile opening and closing edges.
On: The PHOTO input takes on a similar function to the BAR input but inverts the motion for the
distance set with the SPIN parameter if the sensing edge to which it is connected is pressed
during the opening phase (if the photocells in CLOSE are busy, it reverses for 10 cm). The safety
bar
edge connected to the BAR input is only active during the CLOSING phase.
Off: The intervention of the sensing safety edge connected to the BAR input stops the movement
of the gate and inverts the motion for the distance set with the SPIN parameter (if the photocell
in the inversion direction is busy it reverses for 10cm) , both in OPENING and CLOSING.
The PHOT OPEN input resumes the operation of the photocell active in opening.
The opening direction of the motor is selected (see Fig. 4):
MINV
On: Right side motor mount
Off: Left side motor mount
Enable or disable the transition from Automatic to Man Present mode.
The logic is associated with the state of the PED input.
On: If at least one of the inputs: DAS, PHOTO or PHOTC remains active (open contact) for at le-
ast 10 seconds, regardless of the position of the door, the unit switches to Man Present mode
horm
(only the OPEN/ CLOSE/ SWO/ SWC inputs are active), after activating the PED command.
For further safety purposes, it is necessary that during the OPEN/CLOSE command, the
PED input is closed. Use an N.O. key for this function, with automatic release.
Off: Automatic switch disabled.
The logic also works with PHOTOTEST enabled. (OFF)
LOGIC (LOG)
FUNCTION
ON-OFF-(Default)
MEMO
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
25