13) PARAMETERS, LOGIC AND SPECIAL FUNCTIONS
The tables below describe the individual functions available in the control unit.
MENU
Automatic closure time. It is activated only with "TCA" logics :ON
TCA
At the end of the preset time, the control unit starts a new closing operation.
The passage left open by the door/gate leaf during the partial opening controlled by the
Tped
pedestrian inoput, is adjusted.
The value is expressed in percentage on the aggregate value of the stroke.
It adjusts the duration of the OPENING slowdown phase.
tsmo
The value is expressed as a percentage of the total value of the stroke.
See section "How to adjust speed and braking".
It adjusts the duration of the CLOSING slowdown phase.
Tsmc
The value is expressed as a percentage of the total value of the stroke.
See section "How to adjust speed and braking".
The opening and closing speed is adjusted.
IMPORTANT: Change the values of this parameter only by keeping to the weight limits
FSTo
shown in Table 1.
See section "How to adjust speed and braking".
The opening and closing speed is adjusted.
IMPORTANT: Change the values of this parameter only by keeping to the weight limits
fstc
shown in Table 1.
See section "How to adjust speed and braking".
Speed during braking is adjusted.
sldo
See section "How to adjust speed and braking".
Speed during braking is adjusted.
sldc
See section "How to adjust speed and braking".
PMO
The torque applied to motor 2 in the opening* phase is adjusted.
PMC
The torque applied to motor 2 in the closing* phase is adjusted.
The trigger time of the anti-crash device (Encoder) is adjusted during the normal speed phase*.
sEav
0:Off-99: maximum sensibility - 1: minimum sensitivity
The trigger time of the anti-crash device (Encoder) is adjusted during the braking phase*.
sEar
0:Off-99: maximum sensibility - 1: minimum sensitivity
Stop space is adjusted after reaching the opening and closing limit switch. This value is
blo
expressed in centimetres.
See section "How to adjust speed and braking".
Stop space is adjusted after reaching the opening and closing limit switch. This value is
blc
expressed in centimetres.
See section "How to adjust speed and braking".
It is activated with AUX parameter only, preset to value 1.
TLS
The activation time of the service light is adjusted.
Ramp during acceleration. Value expressed in tenths of seconds.
TACC
See section "How to adjust speed and braking".
TDEC
Ramp during deceleration.
Emergency braking, after the activation of PHOT/BAR/STOP
Tbr
tenths of seconds (for adjustment see table 1).
It adjusts the reversal distance that the gate travels following the intervention of the sensing
edge (SAFETY EDGE). During the reversal phase, further interventions of the sensing edge
are ignored, the intervention of the sensing edge causes stopping. If during reversal (in the
spin
OPEN and CLOSE direction) a related photocell (PHOTO or PHOTC) is active, the parameter
is ignored and the reversal space must be minimal (10 cm).
The minimum value 1 equals approximately 20 cm, the maximum value 4 equals approxima-
tely 60 cm.
It selects the operating mode of the SCA output:
0: SCA
1: Service light. The contact closes for the time preset with TLS parameter. The countdown
AUX
starts at the inception of the opening operation.
2: Area light. The contact closes in the opening phase and remains closed for the entire TCA
time. It opens only with closed door.
See wiring shown in figure 17.
24
PARAMETERS (PAR)
FUNCTION
inputs,
the value is expressed in
MIN-MAX-(Default)
MEMO
1-240-(40s)
5-100-(20%)
10-100-(20%)
10-100-(20%)
20-120-(45)
20-120-(45)
10-40-(25)
10-40-(25)
1-99-(85%)
1-99-(85%)
Ø-90-(60%)
Ø-90-(60%)
1-10-(3)
1-10-(3)
1-240-(60s)
1-25-(20)
50-99-(50)
1-20-(7)
1-4-(1)
Ø-2-(Ø)